Connecting photocells in partial stop or obstruction wait (contact NC), see
features programming.
Safety devices
Photocells
Configure contact C1 or CX (NC), input for safety devices such as photocells, which are
compliant with EN 12978 standards.
See programming of input C1 or CX features in:
- C1 reopening while closing. While the gate leaves are closing, opening the contact
causes the inversion of movement until they are completely open;
- C3 partial stop. Gate leaves stop if moving with ensuing automatic closing (if the
automatic closing feature has been inserted);
- C4 obstruction wait, leaves stop if they are moving and start moving again once the
obstruction is removed.
If unused, contacts CX and C1 should be deactivated during programming.
Photocells safety connection (services test)
Upon each open or close command, the board verifies that the safety systems work.
Any malfunction inhibits any command.
Enabling the programming feature.
Programming the features
IMPORTANT! Start programming by performing the first features, that is, Motor Type, Number of Motors,
TOTAL STOP and Self-learning.
DIP
Description of features
Motor type
By default, the control panel manages 001OPP001 gearmotors.
To manage 001OPB001 gearmotors:
select the DIPs as shown and press the PROG key on the board. The LED stays on the buzzer sounds off for 1 s.
To return to default settings, press PROG againg. The LED flashes and the buzzer sounds off twice.
Number of motors
By default, two motors are configured.
To configure a single motor:
select the DIPs as shown and press the PROG key on the board.
To return to default setting, press PROG again. The LED flashes and the buzzer sounds off twice.
Connecting photocells in reopen during closing mode (contact NC). See features
programming.
DIP
LED PRG
PROG
key
⚠
Programming the features is to be done when the
operator is stopped.
When programming is finished, set all DIP switches to OFF.
You can memorize up to 25 maximum users. È
By selecting the feature via DIP switch you can tell
whether the feature is enabled or disabled from the LEDs ON
or OFF.