Prepare suitable piping and ducts for routing the 
electrical cables, ensuring protection against 
mechanical damage.

 

Electrical connections

⚠ 

Respect the envisaged connections.

⚠ 

Improper connection may cause serious damage 
to the control unit.

Mains power supply

⑨ 

brown (phase)

 

blue (common)

⑦ 

earth

Bulb power supply

⑤ 

blue (common)

④ 

brown (phase)

⑥ 

earth

⚠ 

Use a switch button with central zero and 
automatic return.

Putting into operation



All the memorised sequences are timed.



When powered, the control unit emits an acoustic 
signal: 3 beeps.

In addition to the radio control, the unit can also be controlled-
by an external button that is activated after storing the 1st TX.
When the 

UP

 button is pressed, the light comes on. When 

the 

DOWN

 button is pressed, the light goes off .

 

MEMORISING THE TX 



Act within a minute of having powered the control 
unit.

⚠ 

Any other motors or virgin accessories in the range 
of action of the TX must not be powered.

 

DELETING ALL THE MEMORISED TXS

In order to delete all the memorised TXs, refer to Fig. 

 

or hold down the unit programming button for 10 seconds 
until you hear 3 beeps.



This procedure clears all the TXs in the memory.

⚠ 

After deletion, wait 10" before performing other 
operations.

 

TX management

Memorising an additional TX (2nd)

In order to memorise a second TX, refer to Fig. 

 

or press 

the unit programming button briefl y, wait for the beep and 
press 

UP

 on the TX to be memorised.

A maximum of 20 TXs (including weather stations and/or 
timers) can be memorised.



If you attempt to add 21 TXs, the unit beeps 5 times 
in a row, indicating that the memory is full.

Dismantling and disposal

Before proceeding with these operations, it is always 
advisable to check specifi c regulations in force in the 
place of installation. Packaging components (cardboard, 
plastic etc) can be disposed of together with normal 
household waste without any diffi  culty, by simply sepa-
rating the diff erent types of waste and recycling them. 
Other components (circuit boards, transmitter batteries 
etc.), may contain pollutants. They should therefore be 
removed and handed over to companies authorised to 
recover and dispose of them.

DISPOSE OF PROPERLY!

The data and information provided in this manual are subject to 
change at any time without prior notice.

EC Declaration of Incorporation

Came Cancelli Automatici S.p.A. declares that this de-
vice complies with the essential requirements and other 
relevant provisions established in Directives 2006/95/
EC, 2004/108/EC, 1999/5/EC.

To request a true copy, contact Came Cancelli Automatici S.p.A.
For more information or troubleshooting, call the Italian freephone 
number 

800 295830

.

Summary of Contents for RKLT-WL

Page 1: ...Nederlands NL Espa ol ES Deutch DE Fran ais FR RU English EN Polski PL Italiano IT Portugu s PT RKLT WL 119T70551...

Page 2: ...119T70551 119T70551 ver 1 0 1 0 02 2013 119T70551 119T70551 ver 1 0 1 0 02 2013...

Page 3: ...neutral Erdung Lampe Erdung Stromversorgung Stromversorgung Steuerplatine neutral Stromversorgung Steuerplatine Phase Au enschalter Lampe Stromversorgung ES Pulsador contacto encendido bombilla Pulsad...

Page 4: ...x2 x1 2 BEEP 119T70551 119T70551 ver 1 0 1 0 02 2013 119T70551 119T70551 ver 1 0 1 0 02 2013...

Page 5: ...x x 3 BEEP 3 BEEP 119T70551 119T70551 ver 1 0 1 0 02 2013 119T70551 119T70551 ver 1 0 1 0 02 2013...

Page 6: ...o E severamente vietato forare immergere in acqua far cadere martellare deformare inserire chiodioviti smontareomanomettereildispositivo Destinazione d uso Centralina ricevente per controllare tramite...

Page 7: ...sentono 3 beep Con questa procedura si cancellano tutti i TX in memoria Dopo la cancellazione attendere 10 prima di effettuare altre operazioni Gestione TX Memorizzazione di un TX aggiuntivo 2 Per la...

Page 8: ...deform insert nails or screws dismantle or tamper with the device Intended use Receiver control unit for sending commands via a remote control to a lighting system max 500 W Compatible with all trans...

Page 9: ...ore performing other operations TX management Memorising an additional TX 2nd In order to memorise a second TX refer to Fig or press the unit programming button brie y wait for the beep and press UP o...

Page 10: ...u ils ne jouent pas avec l appareil Il est strictement interdit de d percer plonger dans l eau faire tomber marteler d former introduire des clous ou des vis d monter ou alt rer le dispositif Utilisat...

Page 11: ...te proc dure efface tous les TX m moris s Au terme de la suppression attendre 10 avant toute autre op ration Gestion TX M morisation d un TX suppl mentaire 2 me Pour la m morisation d un deuxi me TX s...

Page 12: ...Wasserzutauchen fallenzulassen miteinemHam mer bearbeiten verbiegen mit N geln oder Schrau ben zu durchbohren bzw irgendwie zu ver ndern Verwendungszweck Empfangsstation um mittels mit einem Handsende...

Page 13: ...herten TX gel scht Nach dem L schen 10 warten und erst dann andere Vorg nge vornehmen Steuerung der TX Einspeicherung eines zus tzlichen TX 2 Um einen zus tzlichen TX einzuspeichern die Abb befolgen o...

Page 14: ...lar deformar introducir clavos o tornillos desmontar o adulterar el dispositivo Uso previsto Central receptora para controlar mediante mandos radio impartidos por un telemando una instalaci n de luz M...

Page 15: ...u s del borrado esperar 10 segundos antes de efectuar otras operaciones Gesti n TX Memorizaci n de un emisor adicional 2 Para memorizar otro emisor adicional seguir lo indicado en la Fig o presionar p...

Page 16: ...oduct te doorboren in water onder te dompelen te laten vallen erop te slaan met een hamer te vervormen er spijkers of schroeven in te slaan of te draaien te demonteren of om te bouwen Bedoeld gebruik...

Page 17: ...ammeringstoets van de besturingseenheid ingedrukt tot u 3 bieptonen hoort Met deze procedure worden alle TX uit het geheugen verwijderd Wacht na het verwijderen 10 voordat u wat anders doet Beheer van...

Page 18: ...gos ou parafusos desmontar ou adulterar o dispositivo Destina o de uso Central receptora para controlar atrav s de comandos de r dio efectuados por controlo remoto um sistema de luz m x 500 watt Compa...

Page 19: ...cancelar aguarde 10 antes de efectuar outras opera es Gest o de TX Memoriza o de um TX suplementar 2 Para a memoriza o de um segundo TX adicional consulte a Fig ou pressione brevemente a tecla de pro...

Page 20: ...nie zanurzanie w wodzie dopuszczanie do upadni cia bicie m otkiem zniekszta canie wbijanie gwo dzi lub rub jakte przerabianiesilnika przewoduzasilania Przeznaczenie Centralka odbiorcza przeznaczona do...

Page 21: ...edury wszystkie TX zostan usuni te z pami ci Po usuni ciu odczeka 10 przed wykonaniem innych operacji Zarz dzanie pilotami TX Zapami tanie dodatkowego TX 2 gi Celem zapami tanie drugiego dodatkowego p...

Page 22: ...51 ver 1 0 1 0 02 2013 1 BEEP 1 Came Cancelli Automatici S p 3 RU 500 KLT RKLT WL 500 400 0 C 55 C 230 5 50 433 92 EN 50267 2 1 1 10 3G x 0 75 2 10 20 3G x 1 2 20 30 3G x 1 5 2 FR0R CEI 20 22 CEI EN 5...

Page 23: ...19T70551 ver 1 0 1 0 02 2013 119T70551 119T70551 ver 1 0 1 0 02 2013 17 3 1 1 1 10 3 10 20 20 Tx 21 5 CE Came Cancelli Automatici S p A 2006 95 CE 2004 108 CE 1999 5 CE Came Cancelli Automatici S p A...

Page 24: ...da e qualquer informa o acerca da empresa de produtos e assist ncia t cnica em sua l ngua PL Wszystkie inne informacje dotycz ce rmy produkt w oraz us ug i pomocy technicznej w Waszym j zyku znajduj s...

Reviews: