background image

p.

 

1

0

10

 

- M

an

u

al

 c

od

e: 

11

9

P

M

7

5

11

9

P

M

7

5

 v.

 

44

 1

0

/2

0

14 © C

A

M

E S

.p.

A

. - T

h

e d

ata a

n

d i

n

fo

rm

ati

on i

n th

is

 m

an

u

al

 m

ay b

e c

h

an

g

ed at a

ny ti

m

e a

n

d w

ith

ou

t n

oti

ce

.

ENGLISH

Power supply 230 V AC 50/60 Hz

Power supply

Accessories

Functions selector connection.

  The partial opening function cannot be 

activated from the selector.

  To get the antipanic function without the 

selector, bridge contacts 1-3.

10 - 11 

Accessories power-supply output 24 V AC.

  The connected accessories must not 

exceed 15 W overall.

M - N 

Default gearmotor connection for the PB1001 
arm.

With the PB1002 invert cables M-N.

11 - S 

Electrolock connection 12 V DC - 15 W max.

brown

blue

Summary of Contents for PB1100

Page 1: ...SWING DOOR OPERATOR Installation manual PB1100 119PM75EN English EN ...

Page 2: ...ns Keep gate operation areas clean and free of any obstructions Make sure that the photocells are free of any overgrown vegetation and that the ope rator s area of operation is free of any obstructions Do not allow children to play with fixed commands or to loiter in the gate s maneuvering area Keep any remote control transmitters or any other command devices away from children to prevent the opera...

Page 3: ... 1 2 1 0 8 Maximum gate leaf weight kg 150 200 250 REFERENCE REGULATIONS CAME S p A is certified for the ISO 9001 quality and ISO 14001 environmental management systems This product complies with the current regulations mentioned in the declaration of conformity Intended use This operator is designed to power swing doors for intensive duty Any installation and or use other than that specified in t...

Page 4: ...ply line by means of a dual pole cut off switch with minimum contact openings of 3 mm and section the power supply Set up suitable tubes and conduits for the electric cables to pass through making sure they are protected from any mechanical damage Make sure that any connections inside the casing ones that ensure continuity to the protection circuit are fitted with additional insulation with respec...

Page 5: ...gth 10 20 m Cable length 20 30 m Control panel power supply 230 V AC FROR CEI 20 22 CEI EN 50267 2 1 3G x 1 5 mm2 3G x 2 5 mm2 3G x 4 mm2 Photocell transmitters 2 x 0 5 mm2 2 x 0 5 mm2 2 x 0 5 mm2 Photocell receivers 4 x 0 5 mm2 4 x 0 5 mm2 4 x 0 5 mm2 Command and safety device 2 x 0 5 mm2 2 x 0 5 mm2 2 x 0 5 mm2 If cable lengths differ from those specified in the table establish the cable section...

Page 6: ...nged at any time and without notice ENGLISH Articulated arm PB1002 for push to open doors For details on drilling and fastening the base see the literature about the arm Sliding arm PB1001 for pull to open doors For details on drilling and fastening the base see the literature about the arm up to 120 up to 180 ...

Page 7: ...ce available for fitting the operator and accessories varies depending on where it is being installed It is up to the fitter therefore to choose the most suitable solution Setting up the base Remove the front protective carter using a flat head screwdriver Remove the side plate on the side opposite of the arm hole ⓐ Remove the transformer free up the anchoring base from the case by loosening the n...

Page 8: ... manual may be changed at any time and without notice ENGLISH Fastening the operator After fastening the base to the wall mount the case onto the base while threading the cable into the corresponding holes Mount the required arm Refit the transformer make the required connections and settings ...

Page 9: ... the door runs into an obstacle it reopens if it is closing it recloses if it is opening Warning after three consecutive obstruction detections the door will block For it to resume movement remove the obstruction and press the control button or transmitter button Main components 1 Transformer terminals 2 Batteries terminals 3 Encoder terminals 4 Accessories terminals 5 MA7034 card connector 6 Acce...

Page 10: ... Functions selector connection The partial opening function cannot be activated from the selector To get the antipanic function without the selector bridge contacts 1 3 10 11 Accessories power supply output 24 V AC The connected accessories must not exceed 15 W overall M N Default gearmotor connection for the PB1001 arm With the PB1002 invert cables M N 11 S Electrolock connection 12 V DC 15 W max...

Page 11: ...luding automatic closing To resume movement use the control device The contact is bridged If unused leave it bridged 2 M N O connection for OPENING button even with functions selector in closed doors mode or with DIP switch set to ON for OPENING CLOSING step by step In this case inputs 2 R1 and 2 R2 are excluded 2 R3 N O connection for IMMEDIATE CLOSING button It works only with the door open when...

Page 12: ...by step function on 2 M it excludes automatic closing and contacts 2 R1 and 2 R2 6 ON Wind stop Jolt Stop this function prevents opening of the door leaves in strong winds Wind Stop It is automatically excluded when the battery powered anti panic is activated If the electrolock is connected it facilitates its release Jolt Stop 7 ON Push Go push to open the leaves function It can be excluded by sel...

Page 13: ... set DIP switch 10 to ON press button and release it when the LED turns on Power up the operator the door will proceed at slowed down speed until it closes Manually push the door to the wanted open position and press button release it when the LED turns on Reset DIP switch 10 to OFF Complete the procedure by either powering off or on the control board wait at least 5 seconds Send an opening comman...

Page 14: ...vel speed trimmer and slow downs trimmers on both control boards Warning Cut off the main power supply and if fitted disconnect the batteries Connect the two control boards as shown in the figure On the SLAVE board short circuit terminals 1 2 of the accessories and set DIP switches 1 8 to On the MASTER board set DIP switch 2 to Make all electrical connection only on the MASTER board except for the...

Page 15: ...ANTLING AND DISPOSAL Our products are made with different materials Most of these aluminum plastic iron electrical cables are classified as solid urban waste It can be recycled by separating it before dumping at authorized city dumps Whereas other components control boards batteries transmitters and so on may contain hazardous pollutants These must therefore be disposed of by authorized certified ...

Page 16: ...nformação acerca da empresa de produtos e assistência técnica em sua língua PL Wszystkie inne informacje dotyczące firmy produktów oraz usług i pomocy technicznej w Waszym języku znajdują się na stronie RU Для получения дополнительной информации о компании продукции и сервисной поддержке на вашем языке HU A vállalatra termékeire és a műszaki szervizre vonatkozó minden további információért az Ön ny...