ENGLISH

WARNING!

important safety instructions for people:

READ CAREFULLY!

Premise

• Employ this product only for the use for which it was expressly made. Any 
other use is dangerous. CAME S.p.A is not liable for any damage caused by 
improper, wrongful and unreasonable use • Keep these warnings together 
with the installation and operation manuals that come with the operator.

Before installing

(checking what's there: if something is missing, do not continue until you 
have complied with all safety provisions)
• Check that the automated parts are in good mechanical order, that the 
operator is level and aligned, and that it opens and closes properly. Make 
sure you have suitable mechanical stops • If the operator is to be installed 
at a height of over 2.5 m from the ground or other access level, make 
sure you have any necessary protections and/or warnings in place • If any 
pedestrian openings are fi tted into the operator, there must also be a system 
to block their opening while they are moving • Make sure that the opening 
automated door or gate cannot entrap people against the fi xed parts of the 
operator • Do not install the operator upside down or onto elements that 
could yield and bend. If necessary, add suitable reinforcements to the an-
choring points • Do not install door or gate leaves on tilted surfaces • Make 
sure any sprinkler systems cannot wet the operator from the ground up • 
Make sure the temperature range shown on the product literature is suitable 
to the climate where it will be installed • Follow all instructions as improper 
installation may result in serious bodily injury • It is important to follow these 
instructions for the safety of people.

Installing

• Suitably section off  and demarcate the entire installation site to prevent 
unauthorized persons from entering the area, especially minors and children 
• Be careful when handling operators that weigh over 20 kg. If need be, use 
proper safety hoisting equipment • All opening commands (that is, buttons, 
key switches, magnetic readers, and so on) must be installed at least 1.85 
m from the perimeter of the gate's working area, or where they cannot be 
reached from outside the gate. Also, any direct commands (whether but-
tons, touch panels, and so on) must be installed at least 1.5 m from the 
ground and must not be reachable by unauthorized persons • All maintained 
action commands, must be fi tted in places from which the moving gate lea-
ves and transit and driving areas are visible • Apply, if missing, a permanent 
sign showing the position of the release device • Before delivering to the 
users, make sure the system is EN 12453 standard compliant (regarding 
impact forces), and also make sure the system has been properly adjusted 
and that any safety, protection and manual release devices are working 
properly • Apply Warning Signs (such as the gate's plate) where necessary 
and in a visible place.

Special user-instructions and recommendations

• Keep gate operation areas clean and free of any obstructions. Make sure 
that the photocells are free of any overgrown vegetation and that the ope-
rator's area of operation is free of any obstructions • Do not allow children 
to play with fi xed commands, or to loiter in the gate's maneuvering area. 
Keep any remote control transmitters or any other command devices away 
from children, to prevent the operator from being accidentally activated. 
The apparatus may be used by children of eight years and above and by 
physically, mentally and sensorially challenged people, or even ones without 
any experience, provided this happens under close supervision or once they 
have been properly instructed to use the apparatus safely and to the poten-
tial hazards involved. Children must not play with the apparatus. Cleaning 
and maintenance by users must not be done by children, unless properly 
supervised • Frequently check the system for any malfunctions or signs of 
wear and tear or damage to the moving structures, to the component parts, 
all anchoring points, including cables and any accessible connections.
Keep any hinges, moving joints and slide rails properly lubricated • Perform 
functional checks on the photocells and sensitive safety edges, every six 

months. To check whether the photocells are working, wave an object in 
front of them while the gate is closing; if the operator inverts its direction 
of travel or suddenly stops, the photocells are working properly. This is the 
only maintenance operation to do with the power on. Constantly clean the 
photocells' glass covers using a slightly damp cloth; do not use any sol-
vents or other chemical products that may ruin the devices • If repairs or 
modifi cations are required to the system, release the operator and do not 
use it until safety conditions have been restored • Cut off  the power supply 
before releasing the operator for manual openings and before any other 
operation, to prevent potentially hazardous situations. Check the instruc-
tions • If the power supply cable is damaged, it must be replaced by the 
manufacturer or authorized technical assistance service, or in any case, by 
similarly qualifi ed persons, to prevent any risk • It is FORBIDDEN for users to 
perform any OPERATIONS THAT ARE NOT EXPRESSLY REQUIRED OF THEM 
AND WHICH ARE NOT LISTED in the manuals. For any repairs, modifi cations 
and adjustments and for extra-ordinary maintenance, CALL TECHNICAL 
ASSISTANCE • Log the jobs and checks into the periodic maintenance log. 

Further recommendations for all

• Keep away from hinges and mechanical moving parts • Do not enter 
the operator's area of operation when it is moving • Do not counter the 
operator's movement as this could result in dangerous situations • Always 
pay special attention to any dangerous points, which have to be labelled with 
specifi c pictograms and/or black and yellow stripes • While using a selector 
switch or a command in maintained actions, keep checking that there are no 
persons within the operating range of any moving parts, until the command 
is released • The gate may move at any time and without warning • Always 
cut off  the power supply before performing any maintenance or cleaning 

Danger of hand crushing

Danger! High voltage.

No transiting while gate is moving

Summary of Contents for PB1100

Page 1: ...SWING DOOR OPERATOR Installation manual PB1100 119PM75EN English EN ...

Page 2: ...ns Keep gate operation areas clean and free of any obstructions Make sure that the photocells are free of any overgrown vegetation and that the ope rator s area of operation is free of any obstructions Do not allow children to play with fixed commands or to loiter in the gate s maneuvering area Keep any remote control transmitters or any other command devices away from children to prevent the opera...

Page 3: ... 1 2 1 0 8 Maximum gate leaf weight kg 150 200 250 REFERENCE REGULATIONS CAME S p A is certified for the ISO 9001 quality and ISO 14001 environmental management systems This product complies with the current regulations mentioned in the declaration of conformity Intended use This operator is designed to power swing doors for intensive duty Any installation and or use other than that specified in t...

Page 4: ...ply line by means of a dual pole cut off switch with minimum contact openings of 3 mm and section the power supply Set up suitable tubes and conduits for the electric cables to pass through making sure they are protected from any mechanical damage Make sure that any connections inside the casing ones that ensure continuity to the protection circuit are fitted with additional insulation with respec...

Page 5: ...gth 10 20 m Cable length 20 30 m Control panel power supply 230 V AC FROR CEI 20 22 CEI EN 50267 2 1 3G x 1 5 mm2 3G x 2 5 mm2 3G x 4 mm2 Photocell transmitters 2 x 0 5 mm2 2 x 0 5 mm2 2 x 0 5 mm2 Photocell receivers 4 x 0 5 mm2 4 x 0 5 mm2 4 x 0 5 mm2 Command and safety device 2 x 0 5 mm2 2 x 0 5 mm2 2 x 0 5 mm2 If cable lengths differ from those specified in the table establish the cable section...

Page 6: ...nged at any time and without notice ENGLISH Articulated arm PB1002 for push to open doors For details on drilling and fastening the base see the literature about the arm Sliding arm PB1001 for pull to open doors For details on drilling and fastening the base see the literature about the arm up to 120 up to 180 ...

Page 7: ...ce available for fitting the operator and accessories varies depending on where it is being installed It is up to the fitter therefore to choose the most suitable solution Setting up the base Remove the front protective carter using a flat head screwdriver Remove the side plate on the side opposite of the arm hole ⓐ Remove the transformer free up the anchoring base from the case by loosening the n...

Page 8: ... manual may be changed at any time and without notice ENGLISH Fastening the operator After fastening the base to the wall mount the case onto the base while threading the cable into the corresponding holes Mount the required arm Refit the transformer make the required connections and settings ...

Page 9: ... the door runs into an obstacle it reopens if it is closing it recloses if it is opening Warning after three consecutive obstruction detections the door will block For it to resume movement remove the obstruction and press the control button or transmitter button Main components 1 Transformer terminals 2 Batteries terminals 3 Encoder terminals 4 Accessories terminals 5 MA7034 card connector 6 Acce...

Page 10: ... Functions selector connection The partial opening function cannot be activated from the selector To get the antipanic function without the selector bridge contacts 1 3 10 11 Accessories power supply output 24 V AC The connected accessories must not exceed 15 W overall M N Default gearmotor connection for the PB1001 arm With the PB1002 invert cables M N 11 S Electrolock connection 12 V DC 15 W max...

Page 11: ...luding automatic closing To resume movement use the control device The contact is bridged If unused leave it bridged 2 M N O connection for OPENING button even with functions selector in closed doors mode or with DIP switch set to ON for OPENING CLOSING step by step In this case inputs 2 R1 and 2 R2 are excluded 2 R3 N O connection for IMMEDIATE CLOSING button It works only with the door open when...

Page 12: ...by step function on 2 M it excludes automatic closing and contacts 2 R1 and 2 R2 6 ON Wind stop Jolt Stop this function prevents opening of the door leaves in strong winds Wind Stop It is automatically excluded when the battery powered anti panic is activated If the electrolock is connected it facilitates its release Jolt Stop 7 ON Push Go push to open the leaves function It can be excluded by sel...

Page 13: ... set DIP switch 10 to ON press button and release it when the LED turns on Power up the operator the door will proceed at slowed down speed until it closes Manually push the door to the wanted open position and press button release it when the LED turns on Reset DIP switch 10 to OFF Complete the procedure by either powering off or on the control board wait at least 5 seconds Send an opening comman...

Page 14: ...vel speed trimmer and slow downs trimmers on both control boards Warning Cut off the main power supply and if fitted disconnect the batteries Connect the two control boards as shown in the figure On the SLAVE board short circuit terminals 1 2 of the accessories and set DIP switches 1 8 to On the MASTER board set DIP switch 2 to Make all electrical connection only on the MASTER board except for the...

Page 15: ...ANTLING AND DISPOSAL Our products are made with different materials Most of these aluminum plastic iron electrical cables are classified as solid urban waste It can be recycled by separating it before dumping at authorized city dumps Whereas other components control boards batteries transmitters and so on may contain hazardous pollutants These must therefore be disposed of by authorized certified ...

Page 16: ...nformação acerca da empresa de produtos e assistência técnica em sua língua PL Wszystkie inne informacje dotyczące firmy produktów oraz usług i pomocy technicznej w Waszym języku znajdują się na stronie RU Для получения дополнительной информации о компании продукции и сервисной поддержке на вашем языке HU A vállalatra termékeire és a műszaki szervizre vonatkozó minden további információért az Ön ny...