Command and control devices
Safety devices
2 - R1
(N.O.) connection for outer OPENING sensor,
which is excludable on the selector in EXIT
mode.
2 - R2
(N.O.) connection for inner OPENING or
OBSTRUCTION WAIT sensor.
1 - 2
(N.C.) connection for STOP button.
This is for stopping the door while excluding
automatic closing. To resume movement, use the
control device.
The contact is bridged. If unused, leave it
bridged.
2 - M
(N.O.) connection
for OPENING button even with functions selector
in closed doors mode (
)
or
with DIP switch set to ON, for OPENING/
CLOSING (step-by-step). In this case, inputs
2-R1 and 2-R2 are excluded.
2 - R3
(N.O.) connection for IMMEDIATE CLOSING
button.
It works only with the door open, when it is
waiting for automatic closing.
2 - C1
(N.C.) connection for reopening during closing
photocells.
The contact is used for photocells or other
safety devices, if it is not possible to use the
microphotocells.
If unused, bridge the contact.