P
age
24
- Manual
FA01509-EN
- 05/2021 - © C
AME S.p.A. - The contents of this manual may be changed at any time and without notice. - T
ranslation of the o
riginal instructions
Closing slowdown point
Set the closing slowdown start point, as a percentage of total travel.
This function appears only if the [Encoder] function is active.
F38
Closing slowdown point
5% to 45% (Default 25%)
Save data
Save user data, timings and configurations to the memory device (memory roll).
The function is displayed only when a memory roll card is inserted into the control board.
F50
Save data
0 =Deactivated (Default)
1 = Activated
Read data
Upload user data, timings and configurations to the memory device (memory roll).
The function is displayed only when a memory roll card is inserted into the control board.
F51
Read data
0 =Deactivated (Default)
1 = Activated
Opening direction
Set the gate opening direction.
F54
Opening direction
0 = To the left (default)
1 = To the right
RIO ED T1
Associate one of the available functions with a wireless safety device.
F65
RIO ED T1
OFF (Default)
P0 = It stops the gate and excludes automatic closing. Use a control device to resume
movement.
P7 = Reopen while closing.
P8 = Reclose while opening.
RIO ED T2
Associate one of the available functions with a wireless safety device.
F66
RIO ED T2
OFF (Default)
P0 = It stops the gate and excludes automatic closing. Use a control device to resume
movement.
P7 = Reopen while closing.
P8 = Reclose while opening.
RIO PH T1
Associate one of the available functions with a wireless safety device.
F67
RIO PH T1
OFF (Default)
P1 = Reopen while closing.
P2 = Reclose while opening.
P3 = Partial stop.
P4 = Obstacle standby.