P
age
25
- Manual
FA01509-EN
- 05/2021 - © C
AME S.p.A. - The contents of this manual may be changed at any time and without notice. - T
ranslation of the o
riginal instructions
RIO PH T2
Associate one of the available functions with a wireless safety device.
F68
RIO PH T2
OFF (Default)
P1 = Reopen while closing.
P2 = Reclose while opening.
P3 = Partial stop.
P4 = Obstacle standby.
Partial opening time
Adjust the gate opening time.
This function only appears if function F11 is deactivated.
F71
Partial opening time
From 5 to 40 seconds (default: 5 seconds)
New user
Register up to a maximum of 250 users and assign a function to each one.
The operation can be carried out by using a transmitter. The board AF must be inserted into the connector.
Download the LIST OF REGISTERED USERS form from the docs.came.com portal by typing in L20180423.
U1
New user
1 = Step-by-step
2 = Sequential
3 = Open
4 = Partial opening
Choose the function to be assigned to the user.
Press ENTER to confirm.
Send the code from the control device.
Repeat the procedure to add other users.
Remove user
Remove one of the registered users.
U2
Remove user
OFF
ON
Use the arrows to choose the number associated with the user you want to remove.
No. 1 > 250
Alternatively, the control device associated with the user you want to remove can be
activated.
Press ENTER to confirm.
“CLr” will appear to confirm deletion.
Remove all
Remove all registered users.
U3
Remove all
OFF (Default)
ON
Radio decoding
Choose the type of radio coding for the transmitters enabled to control the operator.
If you choose the type of radio coding for the transmitters [Rolling code] or [TW key block], any transmitters with a different type of radio coding saved
previously will be deleted.
U4
Radio decoding
1 = All decoding (default)
2 = Rolling code
3 = TW key block