Command and control devices
1
Antenna with RG58 cable
2
STOP button (NC contact)
Stop the gate and exclude automatic closing. Use a control device to resume movement.
If the contact is not used, it must be deactivated during programming.
3
Control device (NO contact)
OPEN ONLY or PARTIAL OPENING function
Fully or partially open the gate.
When the [HOLD-TO-RUN] function is active, the control device must be connected during OPENING.
4
Control device (NO contact)
OPEN-CLOSE (step-by-step), OPEN-STOP-CLOSE-STOP (sequential), OPEN ONLY or CLOSE ONLY function
When the [HOLD-TO-RUN] function is active, the control device must be connected during CLOSING.
5
Card reader
6
Transponder selector switch
7
Keypad selector
A B GND
A B
S1 GND
1 2 3P 7
A B GN
B
D
2
3
4
7
6
5
1
Safety devices
Connect the safety devices to the CX, CY and/or CZ inputs (NC contacts).
During programming, configure the type of action that must be performed by the device connected to the input.
If contacts CX and/or CY are not used, they must be deactivated during programming.
DELTA photocells
Standard connection
DELTA photocells
Connection with safety test
See function [F5] Safety devices test.