Automatic closing after partial opening
Set the time before automatic closure is activated, after a partial opening command has been performed.
The function does not work if any of the safety devices are triggered when an obstacle is detected, after a complete stop, during a power outage or if
there is an error.
Do not deactivate the function F19 [Automatic close].
F20
Automatic closing after partial
opening
OFF
1 to 180 seconds (Default 10 seconds)
Pre-flashing time
Set the time for which the beacon is activated before each manoeuvre.
F21
Pre-flashing time
OFF (Default)
1 to 10 seconds
Gate travel speed
Set the travel speed (percentage of maximum speed).
F28
Gate travel speed
50% to 100% (Default 100%)
Slowdown speed
Opening and closing slowdown speed
This function appears only if the [Encoder] function is active.
F30
Slowdown speed
10% to 50% (Default 50%)
Travel sensitivity
Adjust the obstruction detection sensitivity during boom travel.
F34
Travel sensitivity
10% to 100% (Default 100%)
Slowdown sensitivity
Adjust the obstruction detection sensitivity during slowdown.
This function appears only if the [Encoder] function is active.
F35
Slowdown sensitivity
10% to 100% (Default 100%) - 10% = maximum sensitivity - 100% = minimum
sensitivity
Partial opening point
Determine the gate partial opening point, as a percentage of total travel.
This function appears only if the [Encoder] function is active.
F36
Partial opening point
10% to 80% (Default 20%)
Opening slowdown point
Set the opening slowdown start point, as a percentage of total travel.
This function appears only if the [Encoder] function is active.
F37
Opening slowdown point
5% to 45% (Default 25%)