Obstacle with motor stopped
With the function active, the gate remains idle if the safety devices detect an obstacle. The function is active when the gate is closed, open or after a complete stop.
F9
Obst. with motor stopped
OFF (Default)
ON
Gate-open warning light
It signals the gate status.
F10
Gate-open warning light
0 = Warning light on (default) - The warning light stays on when the gate is moving or
open.
1 = Warning light flashing - The warning light flashes every half second when the gate
is opening and stays on when the gate is open. The light flashes every second when
the gate is closing, and remains off when the gate is closed.
Encoder
Manage operator slowdowns, obstacle detection and sensitivity.
F11
Encoder
OFF
ON (Default)
Soft start
Set a slowdown of a few seconds after each opening and closing command.
F12
Soft start
OFF (Default)
ON
Sensor type
Set the type of control device.
F14
Sensor type
0 = Transponder selector switch
1 = Keypad selector (default)
Additional light
Choose the operating mode of the lighting device connected to the output.
F18
Additional light
0 =Flashing beacon (Default)
1 = Cycle light.
The light remains off if an automatic closing time is not set.
Automatic closure
Set the time before automatic closure is activated, once the opening travel end point has been reached.
The function does not work if any of the safety devices are triggered when an obstacle is detected, after a complete stop, during a power outage or if
there is an error.
F19
Automatic closure
OFF (Default)
From 1 to 180 seconds