Installation Guide for RFU-D-HP
Page 32 of 179
Grounding the Cables
To fit the gland, the outer cable diameter should be between 6-10 mm.
Cables must be grounded as follows.
•
For fiber cables (see
Connecting an Optical Fiber Cable and SFP
on page 48), no grounding is required.
•
on page 53), no grounding is required.
•
For CAT-5e/CAT-6 cables (see
Connecting a CAT-5e/CAT-6 Data
Cable on page 55), the shielded Ethernet cable
(SF/UTP construction)
must
be grounded to the antenna tower at the top (next to the RFU), the entry to the indoor
cabinet, and every 50m using the kit CAT6a_gnd_kit.
1
2
3
4
5
6
7
8
9
10
11
12
13
Figure 20: Cable Grounding
Table 6: Cable Grounding Kit
Marketing Model
Description
N000082L173A
PTP 820 High Speed GND Kit for CAT6A Cable
Summary of Contents for PTP 820 Series
Page 1: ...Installation Guide ...
Page 69: ...Installation Guide for RFU D HP Page 69 of 179 ...
Page 75: ...Installation Guide for RFU D HP Page 75 of 179 ...
Page 91: ...Installation Guide for RFU D HP Page 91 of 179 ...
Page 93: ...Installation Guide for RFU D HP Page 93 of 179 ...
Page 102: ...Installation Guide for RFU D HP Page 102 of 179 ...
Page 120: ...Installation Guide for RFU D HP Page 120 of 179 ...
Page 143: ...Installation Guide for RFU D HP Page 143 of 179 1 4 2 5 3 OCU ...