Installation Guide for RFU-D-HP
Page 80 of 179
Required Tools
•
Metric offset hexagon key set
•
Metric wrench key set
Procedure
1 Prior
to the installation, follow the antenna manufacturer’s instructions to use the circular adaptor.
(Remove the existing rectangular transition, swap the O-ring, and install the circular transition instead.)
2 Connect the RFU-D-HP OMT Kit to the antenna and secure it with four screws. Verify existence of the O-
ring.
Note:
Verify that the O-ring is properly mounted between the antenna transition and the OMT.
3 Connect the RFU-D-HP Dual Coupler Kit to the OMT Kit using four M8 screws and washers, and tighten
the screws.
Note:
Verify that the O-rings are properly mounted between the OMT ports and the dual coupler.