Chapter 2: System hardware
68
ODU LED Display
LED Labels
SES/SYN
ETH
PWR
3 GHz 4 50 b diagnost ics LEDs
Figure 14 :
3 GHz 450b diagnostic LEDs, viewed from below
The 3 GHz 450b has its status LEDs located beneath the cover behind the
dish. During installation, the LEDs can be viewed by unclipping the rear
most door
For clarity, the cover has been removed to show the location of the LEDs
Table 40 :450i/450 SM/BHS LED descriptions
Status information provided
LED
Color
when
active
SM / BHS in
“Operating”
Mode
SM / BHS in “Aiming” Mode
Note
PWR
Red
DC power
Always lit after 10-20
seconds of power on.
SYN/1
Yellow
Presence of
sync
These three LEDs act as a bar graph to
indicate the relative quality of alignment.
As power level improves during
alignment, more of these LEDs are lit.
Lit when SM/BHS is in
sync
with
an
AP/BHM.
SES/2
Green
Session
Indicator
Lit when SM/BHS is in
session.