User Manual
AMETEK Programmable Power
BPS Series
91
If this field is set incorrectly, the current limit scaling and current
measurement will be off by a factor of three. Changes made to the
SYSTEM field will not take effect until
AFTER
power on the BPS
system is cycled. (Off, then back on).
CONFIGURATION SETUP 4
LAN
This field indicates the presence of the LAN Ethernet interface option.
ON indicates the option is present, N/A indicates the option is not
installed. Not all features indicated are available on this model.
5.2.9
MEASUREMENT CAL FACTORS Menu
Figure 5-23: MEASUREMENT CAL FACTORS Menu.
The MEASUREMENT CAL FACTORS menu provides access to the measurement calibration
parameters. The parameters apply to the selected mode of operation (AC mode only). For three phase
configurations, the PHASE keys toggle between the three calibration screens for each phase. These
parameters are password protected and can only be changed after the calibration password has been
entered. Refer to the calibration section in this manual for details on performing a calibration.
Entry Description
VOLT FS
Full scale voltage measurement calibration factor.
CURR FS
Full scale current measurement calibration factor.