AMETEK Programmable Power
BPS Series User Manual M440077-01 Rev A
19
Displays:
LCD graphics display:
A large high contrast LCD display with backlight provides easy to read guidance
through all setup operations. An adjustable viewing angle makes it easy to read from
all practical locations.
Status indicators:
Large and bright status indicators inform the user of important power source
conditions. The Remote lamp informs the user that the unit is under remote control.
The Overload lamp indicates that excessive current is being drawn at the output. The
Over temperature lamp illuminates when internal heat sink temperatures are too high.
The Hi Range indicator is lit any time the unit is switched to the high voltage range.
The Output On/Off indicator is on when the power source output relays are closed.
2.6
Special Features and Options
Controller Features
Parallel Operation:
Two BPS75 or BPS90 units can be paralleled in a three-phase configuration (with one
master controller and one auxiliary unit) for 150KVA and 180KVA systems. Only the
master unit requires a controller in this setup. The auxiliary units are controlled through
the system interface connector.
Controller: Programmable
controller front panel assembly.
Output Relay:
Standard output relay feature to isolate power source from the load.
Output On/Off:
The output relay can be used to quickly disconnect the load. A green status indicator
displays the status of the output relay.
Firmware / Software / Hardware Options
- HV
Adds 400 V AC only output range.
-ES
Emergency Shut off switch. This option key lock push button is installed on the front
panel of the master BPS if ordered with the BPS system. When pushed in, the main AC
contactor is opened disconnecting the AC input power to the BPS input transformer.
Note that the controller (and LCD display) will still be powered up but no power is
available to the amplifiers and there will be no output power either. The controller runs
off the LV supply, which must be turned off with the front panel breaker.
After the ES has been pushed, the provided key will be required to release it. Once the
ES button has been released, the BPS
must
be powered down using the front panel
circuit breaker and turned back on to start up again.
Note:
Do not misplace the 2 keys provided, as no duplicates are available from CI. If
lost, the ES switch must be replaced. In that case, contact AMETEK Programmable
Power customer service. (
).
-LAN
Adds Ethernet interface (RJ45 connector) for local area network connection.
-LF
Limits maximum output frequency to 500 Hz.