User Manual
AMETEK Programmable Power
BPS Series
89
5.2.8.4
LIMIT SETUP screen
Figure 5-21: LIMIT SETUP Menu
The limit setup screen is not a menu but only serves to inform the user of the hardware capabilities of the
AC source. The cursor can be moved to any of the fields in this screen but none of these fields can be
changed. The following information is provided on this screen:
Entry Description
VOLTAGE
Maximum AC rms or DC voltage available in the high voltage range.
CUR LIMIT
Maximum AC rms current limit available in the low voltage range.
FREQ LO
Lowest possible fundamental frequency that can be programmed.
FREQ HI
Highest possible fundamental frequency that can be programmed.
PHASE C
Phase angle of phase C with respect to phase A in three phase mode. If
the AC source is a single phase model, this field will shown 0°. If the
AC source is a split phase model, this field will shown 180°.