ITC 220 Base Station Transceiver Installation Guide PN 133991 Rev. A
| Page 62
System setup for measuring and adjusting RF power output
Figure 25 Base Station Transmitter power output measurement and adjustment setup
Configure the Agilent E4417A power meter
Use these settings:
Select Channel
Sensor Mode: Normal
Range: Auto
Filter: Auto
Duty Cycle: Off
Offset On: Use offset from cable and attenuator
Frequency: 221.137 MHz
CF Table: Off
FDO Table: Off
Video Avg: Off
Video B/W: Low
Step Detect: On
Gates
-
Gate Start: 3 ms
-
Gate Length: 97 ms
Trace Setup
-
Start: 1 ms
-
Length: 99 ms
Trigger
-
Cont Trig
Measure Setup