P4, P5, and P6 Barbecue Grills
LTR50001137, Rev. K
Appendix
www.calflamebbq.com
34
1.
Disconnect or shut off the LP or natural gas line
connected to the grill. Wait until the burners cool
down.
2.
Open the hood and remove the grate and flame
tamer on top of the stainless steel burner you
want to replace.
3.
Through the access door underneath the grill,
find the round stud and locking pin that locks the
burner you want to replace.
4.
Carefully remove the locking pin with your fingers.
5.
Raise the stud from the locking hole and carefully
move the burner forward to release it from the
igniter and gas supply valve.
6.
Take the burner out of the grill and store it in a
safe and dry place.
7.
Install the Sear Zone burner. Align the gas inlet on
the burner with the gas supply valve on the grill
and torch tube with the igniter. Make sure they
align perfectly. Slide the stud at the other end
into the locking hole.
8.
Adjust the Sear Zone burner, make sure the burner
is aligned and in position.
9.
Repeat steps 2 through 9 if you want to replace
other burners.
10.
Put back the grate you just removed. (You don’t
need flame tamers for Sear Zone burners.)
11.
Reconnect or turn on the gas line.
If you want to change Sear Zone burners to regular
burners, just follow the above procedure above in a
similar way.
Installing Sear Zone Burners