background image

8  —  4805-C3_01 A

eQuinox

WARNING: IF YOU FEEL DISCOMFORT OR ARE EXPERIENC-
ING A MEDICAL EMERGENCY, SEEK MEDICAL ASSISTANCE 
IMMEDIATELY.

WARNING: OPERATING THE OXYGEN CONCENTRATOR OUTSIDE OF 
THE OPERATIONAL TEMPERATURE SPECIFICATIONS CAN LIMIT THE 
CONCENTRATOR’S ABILITY TO MEET OXYGEN CONCENTRATION SPEC-
IFICATION. REFER TO THE SPECIFICATION SECTION OF THIS MANUAL 
FOR TEMPERATURE LIMITS.
WARNING: USE NO OIL, GREASE, OR PETROLEUM-BASED OR OTHER 
FLAMMABLE PRODUCTS WITH THE OXYGEN-CARRYING ACCESSORIES 
OR THE OXYGEN CONCENTRATOR. ONLY WATER BASED, OXYGEN 
COMPATIBLE LOTIONS OR SALVES SHOULD BE USED. OXYGEN ACCEL-
ERATES THE COMBUSTION OF FLAMMABLE SUBSTANCES.
WARNING: THE INCORRECT USE OF THE BATTERY CAN CAUSE THE 
BATTERY TO GET HOT, IGNITE, AND MAY CAUSE SERIOUS INJURY. BE 
SURE NOT TO PIERCE, STRIKE, STEP ON, DROP THE BATTERY, OR OTH-
ERWISE SUBJECT THE BATTERY TO STRONG IMPACTS OR SHOCKS. THE 
USE OF A DAMAGED BATTERY MAY CAUSE PERSONAL INJURY.
WARNING: WHILE USING THE PORTABLE OXYGEN CONCENTRATOR 
OUTDOORS WITH THE AC POWER SUPPLY, CONNECT THE POWER SUP-
PLY INTO A GROUND FAULT INTERRUPTED (GFI) OUTLET ONLY.
WARNING: THE OXYGEN CONCENTRATOR SHOULD NOT BE USED AD-
JACENT TO OR STACKED WITH OTHER EQUIPMENT. IF ADJACENT OR 
STACKED USE IS UNAVOIDABLE, THE DEVICE SHOULD BE OBSERVED 
TO VERIFY NORMAL OPERATION.

CAUTION: In the event of an alarm or you observe the 
Oxygen Concentrator is not working properly; consult 
the Troubleshooting section in this manual. If you cannot 

resolve the problem, consult your Equipment Provider.
CAUTION: To prevent a void warranty, follow all manufacturers’ 
instructions.

WARNING: SMOKING WHILE USING OXYGEN IS THE NUM-
BER ONE CAUSE OF FIRE INJURIES AND RELATED DEATHS.  
YOU MUST FOLLOW THESE SAFETY WARNINGS:

WARNING: DO NOT ALLOW SMOKING, CANDLES, OR OPEN FLAMES 
IN THE SAME ROOM WITH THE DEVICE OR THE OXYGEN-CARRYING 
ACCESSORIES. 
WARNING: SMOKING WHILE WEARING AN OXYGEN CANNULA MAY 
CAUSE FACIAL BURNS AND POSSIBLY DEATH.
WARNING: IF YOU SMOKE, THESE 3 STEPS MAY SAVE YOUR LIFE: 
TURN OFF THE OXYGEN CONCENTRATOR, TAKE OFF THE CANNULA, 
AND LEAVE THE ROOM WHERE THIS DEVICE IS LOCATED. 
WARNING: “NO SMOKING – OXYGEN IN USE” SIGNS MUST BE 
PROMINENTLY DISPLAYED IN THE HOME, OR WHERE OXYGEN IS IN 
USE. PATIENTS AND THEIR CAREGIVERS MUST BE INFORMED ABOUT 
THE DANGERS OF SMOKING IN THE PRESENCE OF, OR WHILE USING, 
MEDICAL OXYGEN.
WARNING: DO NOT USE YOUR OXYGEN CONCENTRATOR IN THE 
PRESENCE OF FLAMMABLE GASES. THIS CAN RESULT IN RAPID 
BURNING CAUSING PROPERTY DAMAGE, BODILY INJURIES OR 
DEATH.
WARNING: REMOVING THE CANNULA AND PUTTING IT ON CLOTH-
ING, BEDDING, SOFAS, OR OTHER CUSHION MATERIAL WILL CAUSE 
A FLASH FIRE WHEN EXPOSED TO A CIGARETTE, HEAT SOURCE, OR 
FLAME. 
WARNING: DO NOT LEAVE A NASAL CANNULA ON OR UNDER CLOTH-
ING, BED COVERINGS OR CHAIR CUSHIONS. IF THE UNIT IS TURNED 
ON BUT NOT IN USE, THE OXYGEN WILL MAKE THE MATERIAL FLAM-
MABLE. SET THE I/0 POWER SWITCH TO THE 0 (OFF) POSITION WHEN 
THE PORTABLE CONCENTRATOR

 

 IS NOT IN USE.

WARNING: DO NOT ATTEMPT ANY MAINTENANCE OTHER 
THAN THE POSSIBLE SOLUTIONS LISTED WITHIN THIS 
MANUAL. DO NOT REMOVE COVERS, ONLY YOUR EQUIP-

MENT PROVIDER OR A QUALIFIED SERVICE TECHNICIAN SHOULD 
REMOVE THE COVERS OR SERVICE THIS DEVICE. 
WARNING: ONLY ACCESSORIES RECOMMENDED BY THE MANUFAC-
TURER. USE OF ANY OTHER MAY BE HAZARDOUS, CAUSE SERIOUS 
DAMAGE TO YOUR OXYGEN CONCENTRATOR AND WILL VOID THE 
WARRANTY .

CAUTION: Always disconnect AC power supply from the 
wall before disconnection the AC power supply from the 
oxygen concentrator.

CAUTION: Always place oxygen supply tubing and power cords in a 
manner that prevents a trip hazard.
CAUTION: When using the Oxygen Concentrator in an automobile, 
boat, or on other DC sources with the 12VDC Cable, make sure that 
the vehicle is started and running before connecting the Oxygen 
Concentrator. If the 12VDC Cable does not illuminate and requires 
resetting, disconnect the 12VDC Cable from the DC outlet, restart 
your vehicle, and then reconnect your 12VDC Cable into the DC 
outlet. Failure to follow these instructions can result in the power 
supply not supplying power to the Oxygen Concentrator.
CAUTION: When the automobile in which you are using the Oxygen 
Concentrator unit is turned off, disconnect and remove the device 
from the automobile. Do not store the Oxygen Concentrator in a 
very hot or cold automobile or in other similar, high-or low-tem-
perature environments.

Note: Portable and mobile RF communications equipment can effect 
medical electrical equipment.

WARNING: THE MANUFACTURER RECOMMENDS AN ALTER-
NATE SOURCE OF SUPPLEMENTAL OXYGEN IN THE EVENT 
OF A POWER OUTAGE, ALARM CONDITION, OR MECHANI-
CAL FAILURE. CONSULT YOUR PHYSICIAN OR EQUIPMENT 

PROVIDER FOR THE TYPE OF RESERVE SYSTEM REQUIRED. 
WARNING: DO NOT ALLOW EITHER THE AIR INTAKE OR THE AIR 
OUTLET VENTS TO BECOME BLOCKED. DO NOT DROP OR INSERT ANY 
OBJECTS INTO ANY OPENINGS ON THE DEVICE. THIS CAN CAUSE THE 
OXYGEN CONCENTRATOR TO OVERHEAT AND IMPAIR PERFORMANCE.

Summary of Contents for eQuinox

Page 1: ...eQuinoxTM User Manual eQuinox...

Page 2: ...Output Do not get wet Type B Applied Part degree of protection against electric shock the applicable U S and Canadian standards Recycle Symbol This device complies with the requirements of Directive 9...

Page 3: ...ations for Use 7 Contraindications for Use 7 Safety Guidelines 7 Recommended Operating Environments 9 Operating Instructions 10 First Time eQuinox Operation 14 User Troubleshooting Table 16 Cleaning C...

Page 4: ...s Cautions and additional device information in the rest of this manual Become familiar with the key features of the eQuinox and the User Control Panel BACK Power Cartridge Latch Exhaust Vent Power Ca...

Page 5: ...Pulse Dose Mode Indicator illuminates and a pulse of oxygen is delivered with each inspiratory effort ALERT Yellow Indicator Low and Medium Priority Alerts When illuminated this indicates a low priori...

Page 6: ...g the eQuinox 7 Universal Cart Operation Flow Mode Button and Indicator Pressing this button repeatedly will toggle you back and forth between 0 5 and 3 0 LPM In Pulse Dose Mode oxygen is supplied in...

Page 7: ...S WITHIN THE SAME ROOM OF 1 THIS DEVICE OR 2 ANY OXYGEN CARRYING ACCESSORY FAILURE TO OBSERVE THIS WARNING CAN RESULT IN SEVERE FIRE PROPERTY DAMAGE AND OR CAUSE PHYSICAL INJURY OR DEATH WARNING DO NO...

Page 8: ...XYGEN CONCENTRATOR IN THE PRESENCE OF FLAMMABLE GASES THIS CAN RESULT IN RAPID BURNING CAUSING PROPERTY DAMAGE BODILY INJURIES OR DEATH WARNING REMOVING THE CANNULA AND PUTTING IT ON CLOTH ING BEDDING...

Page 9: ...rmal operating temperature before being turned on Refer to the Specifications section in this manual Note When the automobile in which you are using the Oxygen Con centrator unit is turned off disconn...

Page 10: ...wer source and replenish the battery Proper connection of the AC Supply or 12VDC cable requires aligning the power plug with the recessed external power receptacle on the eQuinox The recessed external...

Page 11: ...Flow Setting Continuous Bolus Size mL Pulse 0 5 Yes 1 0 Yes 16 Yes 1 5 Yes 24 Yes 2 0 Yes 32 Yes 2 5 Yes 40 Yes 3 0 Yes 48 Yes 56 Yes 64 Yes 72 Yes 80 Yes 88 Yes 96 Yes 128 Yes 160 Yes 192 Yes Note W...

Page 12: ...if not fully charged or too warm If the Battery is not present or fully discharged during an AC power interruption the eQuinox will shut down and alarm The Battery is fully discharged when the Power...

Page 13: ...ry charges when in the device is operating on AC power only The Battery will also charge from the optional Desktop Charger Typical New Power Cartridge Operating Times Operating Type Battery Type 12 ce...

Page 14: ...ulse Dose Mode and Continuous Flow Mode The proper mode and proper setting should be prescribed for you by your physician Continuous Flow Mode Operation When operating in the Continuous Flow Mode a co...

Page 15: ...for use with the Oxygen Concentrator Nasal Cannula with 7 feet 2 1 m of tubing PN 5408 SEQ For any additional recommended accessories please see the Accessories Catalog PN ML LOX0010 available on www...

Page 16: ...re adequate air flow Filter restricted Clean or replace Air Inlet Filter Position your eQuinox to ensure adequate air flow Exceeding maximum breath rate in Pulse Dose mode See Pulse Dose mode Breath R...

Page 17: ...you with cleaning disinfection and replacement information Cleaning Care Routine Maintenance CAUTION Do not operate the Oxygen Concentrator with out the air intake filter in place If a second filter i...

Page 18: ...Cable Power Cord and Outer Case Turn OFF the eQuinox and disconnect from AC or DC power before any cleaning or disinfection activity DO NOT spray the outer case directly Use a damp not wet cloth or s...

Page 19: ...92 1 2 3 4 5 6 7 8 8 9 Table is based on 15 Breaths Per Minute for Pulse Dose Mode only Pulse Dose Mode Power Cartridge Airline Travel Table mL SETTING FLIGHT LENGTH in Hrs During taxi take off and la...

Page 20: ...82 2473 Worldwide www CAIREmedical com Medical Product Services GmbH Borngasse 20 35619 Braunfels Germany Worldwide www CAIREmedical com PN 4805 C3_01 A Chart SeQual Technologies Inc reserves the righ...