ENCORE VENTI Rev. 3 2021-10
www.cafection.com 800-561-6162
84
SERVICE & INSTALLATION MANUAL for Cafection's Encore Venti
A
n
n
ex
2
ANNEX 2 MONTHLY MAINTENANCE SCHEDULE
MONTHLY MAINTENANCE SCHEDULE
All important parts of the unit must be maintained as per the Maintenance Schedule to honor the warranty and to
avoid possible defects. Adequate maintenance will extend the life of the coffee machine and deliver a consistent
high quality beverage.
ENCORE Series
MVF 04-2017
PERFORMED BY THE SER
VICE PROVIDER
Clean the brew group with a commercial urn cleaner.
PREVENTIVE MAINTENANCE SCHEDULE AT DIFFERENT CYCLES
Check & replace the outlet valves.
Check & replace the water filter.
10,000 cycles
5,000 cycles
Replace the brew group via Cafection’s Brew Group Exchange Program.
Replace the whipping motor(s).
25,000 cycles
Delime the water tank & outlet valves.
50,000 cycles
Replace the grinder burrs.
Replace the water tank float, the heater switch & the water level switch.
100,000 cycles
MONTHLY MAINTENANCE
Clean the brew group with a commercial urn cleaner:
Clean the soluble canisters.
Clean the bean hopper & its funnel.
Clean the stainless coffee chute.
Inspect the fan & clean as needed.
• Open the machine door.
• Add one (1) tablet of commercial urn cleaner in the brewing chamber.
Leave the filter paper in place.
• In Service mode, press on the“Clean Brew Group (Tabz)” button.
• Follow the instructions on the screen.
• Order two (2) coffee drinks to complete the filter paper installation, then close the door.