Water Line Connection
This equipment must be installed in compliance with applicable federal, state,
provincial and/or municipal plumbing codes having jurisdiction.
Make sure the equipment is unplugged before proceeding with the water supply
installation. Also verify that the incoming water pressure is greater than 20 psi and
no more than 80 psi.
1. Prior to installing the equipment, flush out the water line by running approximately 1 gallon of
water into a pail. This will ensure no sediment from a new installation gets in the equipment.
2. The incoming water supply must have a shut-off valve connected in-line. Water supply should
be a plastic 1/4” or 3/8” (outside diameter) dedicated line branched off a larger supply line.
3. Make sure the water source is turned off.
Firmly secure the inlet fitting onto the inlet valve.
Do not overtighten
.
4. Make sure the equipment is unplugged.
Connect the water line to the quick connect inlet
fitting.
5. Turn the water valve on, sending water to the brewer. If there are any leaks, tighten
connections to stop leakage.
This procedure does not take into consideration the installation of a water filtration
system. Please refer to the water filter manufacturer installation instructions and
incorporate them into the above procedures.
Water inlet