9.2
Shutdown and Storage
If this brewing equipment needs to be stored for an extended period of time, follow this procedure
to avoid any risk of damage to the machine.
1. Turn off the unit and unplug it from the power outlet.
2. Completely drain the hot water tank (see section 9.1).
3. Empty the soluble canisters and bean hopper.
4. Clean all parts of the unit (see section 7).
5. Disconnect the white wire from the heating element (see section 3.7).
6. Tie down the water level switch’s arm with a cable tie ("tie-wrap") to keep the float still during
transportation.
Do not overtighten, as this may damage the switch. The purpose of this operation is
only to keep the float from bouncing on the switch.
9.2.1 Storing the Brew Group
It is important to store the brew group properly when it is not installed in the brewer. Always
disengage the brew group clutch using the provided tool to turn the pin clockwise until the
brew chamber lifts up. This action will release the pressure on the screen and seal. The
brew group must be stored on its back or its left side.
Do not sit the brew group on its right side (on the wheels and yoke) or straight up,
as these positions make it unstable and could cause it to fall.