ENCORE LITE Rev. 3 05/2018
65
www.cafection.com 800-561-6162
SERVICE & INSTALLATION MANUAL for Cafection's Encore Lite
C
le
an
in
g
an
d
San
it
iz
in
g
7.8.4 Brew Group
Brew Chamber and Funnel
Frequency: weekly or every 200 cycles
1. Place a large cup or container under the
dispensing nozzle to collect the hot rinse water.
2. Perform several rinse cycles (see section 7.1).
3. Remove the brown tube from its support. Remove
the brew chamber's funnel to dislodge coffee
residue trapped underneath it and rinse it under
hot water.
4. Reinstall the funnel and the tube in its support.
Make sure the tube is against the wall of the
funnel. Water must form a circular motion when
being dispensed.
5. Order a large coffee to ensure that the brew
chamber is working properly.
Warning! Place a container large enough (size
specified on the screen). Water is VERY HOT.
The funnel should be cleaned weekly or more often,
if needed. To clean the funnel, follow steps 3 to 5 of
section 7.8.4.
Brew Group Assembly
Frequency: monthly or every 1,000 cycles
In order to maintain optimal performance of the brew
group assembly, it is recommended to remove it from
the unit, clean it and rinse it under hot water.
1. Open the brewer's door and remove the front
panel.
2. Cut the filter paper with scissors on both sides of the
brew chamber.
3. Flip up the retaining rod, push the locking pin to the
right, then down to release the brew group and pull
it outward.
4. Rinse the brew group thoroughly under hot water
to remove visible soil.
5. Remove the funnel from the brew chamber and
rinse it thoroughly under hot water.
6. Air dry completely before reinstalling the parts.
7. Order a large coffee to ensure that the brew group
is working properly.
The brew group assembly can also be cleaned using
urn cleaner. See section 7.2 for cleaning instructions.
Brew
chamber
Brew chamber's
funnel
Brew chamber
tube retainer