8.4
Hot Water Tank
Inspection: quarterly
Preventive maintenance: every 60,000 cycles
To avoid any issue related to mineral
deposits, Cafection recommends having the
water tank assembly delimed to remove all
scale in the unit. The heating element, the
temperature probe, the water level and the
heater safety switches may also need to be
replaced.
Use a scale remover product such
as
Scale Kleen
by Everpure. See the
manufacturer's instructions for more
details.
The float, the heater switch and the
water level switch of the tank should
be replaced after 100,000 cycles.
1. Turn off the machine and remove
the back panel.
2. Unplug the tank lid's connectors
(see section 8.3, fig.1.1) and the
probe connector.
3. Completely drain water from the
tank (see section 9.1).
4. Remove the tubes (valve and
water tank).
5. Unscrew the guard to be able to
remove the tank.
Heater safety switch
Water level switch
Heating
element
Float
Probe
Tank guard
Probe
connector