Battery Configuration/C-Codes 6
29
Parameter
Description
End of Discharge
The threshold point at which the discharge cycle is
terminated. Chemistry dependent.
Available settings: 0.76-1.12V/Cell (NiCd, NiMH);
1.36-1.95V/Cell (SLA); 2.30-3.20V/Cell (Li-Ion).
End of Recondition
(NiCd and NiMH only)
The threshold point at which the reconditioning cycle is
complete.
Available settings: Disabled or 0.40-0.80V/Cell.
Charge Method
(NiCd and NiMH only)
Allows setting of Reverse Load. The Reverse Load
method intersperses discharge pulses between charge
pulses to keep batteries cool and promotes the
recombination of gases.
Available settings: DC Charge, No Rev Load, Rev
Load 5-12%.
Max. Standby Voltage
(SLA and Li-Ion only)
Maintains the battery at full charge state after service
is complete.
Available settings: 2.15-2.45V/Cell (SLA); 3.90-
4.35V/Cell (Li-Ion).
Max. Charge Voltage
(SLA and Li-Ion only)
The threshold point at which the analyzer stops
charging the battery. At this point, the current charge
drops while maintaining the Max. Charge Voltage.
Available settings: 2.20-2.65V/Cell (SLA); 3.90-
4.35V/Cell (Li-Ion).
End of Charge
(SLA and Li-Ion only)
Detects full charge state. When the End of Charge
condition is reached (Charge rate difference is less
than the specified value), the battery is considered fully
charged and the analyzer completes the charge cycle
on the battery. From 0.01 to 0.10C.