Fig. 105 - Diffuser assembly
Fig. 106 - Athena in the corner
Corner installation is prohibited. The rear hot air causes the stove to overheat which triggers the thermostat
alarm
Fig. 106
.
6.20 ELECTRIC CONNECTION
Warning: the appliance must be installed by an authorized technician!
• The electric connection occurs through a cable with plug put in an electric socket which is able to support charge and tension
specific of every model, as described in the technical datas table (see
FEATURES a pag. 40
).
• The plug must be easily accessible when the appliance is installed.
• Please further assure you that your network is endowed with an efficient earth connection: if it does not exist or if it is not
efficient, please endow you with one in compliance with the law.
• Connect the supply cable first on the back of the stove (see
Fig. 107
and
Fig. 108
) and then at a wall electric socket.
Fig. 107 - Electric socket with master switch
Fig. 108 - Plug connected
• Do not use extension cables.
• If the feeder cable is damaged, it must be replaced by an authorized technician.
• When the stove is not going to be used for a long period of time, it advisable to remove the plug from the socket on the wall.
• An electrical connection to a UPS/ACCUMULATOR/ STABILISER must guarantee a voltage of at least 210 V without power
surges. Considering the variety of UPS on the market regarding size and construction qualities, we cannot guarantee operation
once the stove is connected to these devices.
6.21 STOVE CALIBRATION AND DEPRESSION MEASUREMENT
This stove has a pickup point positioned on the tank in order to measure the depression of the combustion chamber and verify its
proper operation.
To do this, proceed as follows:
• Unscrew nut “D” on the rear of the stove and connect a digital pressure switch with a tube to detect the negative pressure (see
Fig. 109
or
Fig. 110
).
• Load the feed screw via appropriate function.
• Start the stove and set "Set_Flame" to power 1 (the start-up time of this stove lasts between 8 and 10 minutes to ensure
minimum draught).