![background image](http://html1.mh-extra.com/html/cadac/b-type/b-type_installation-and-user-manual_3239265066.webp)
4-10
Input Channel module 7889
B-Type
Revision B2005-2
71417:
'&
#
*URXS
#
GLVSOD\
A 7 segment LED unit that displays the DC Master Group number selected by the “+”
and “-” switches.
71417;
0XWH
#
9&$
When VCA Mute is ON and AUX VCA is ON, then any signal controlled by the fader
is muted, and no signal is passed through the channel. VCA mute is a programmable
function.
71417<
¶5HDG\·
#
,QGLFDWRU
The RDY LED is associated with the motor fader functions SAFE, READY and
WRITE.
The following information only applies to modules fitted with a motor fader.
RDY LED
ModeSystem response
Off
SAFENo dynamic data will be sent from the fader to the PC,
but the fader will respond to data from the PC.
On
READYThe fader is ready to send data to the PC, but no data
will be sent until WRITE Mode is invoked by touching the
fader knob.
Flash
WRITEAs soon as the fader knob is touched, dynamic data is
sent to the PC. The fader will not respond to data sent
from the PC until the fader knob is released.
Full details on using the SAFE/READY/WRITE modes can be found in the SAM
(Sound Automation Manager) user manual.
714183
0RGXOH
#
,VRODWH
When ISO is ON, the module is effectively disconnected from the computer system.
It cannot send commands to the computer, or receive commands from the computer.
The module responds as though it were a manual unit.
714184
&KDQQHO
#
0XWH
A Mute switch is included on each channel to allow the operator to instantaneously
switch off the audio signal without disturbing the ‘fader balance’.
The MUTE switch also has a secondary function when used in conjunction with the
CHECK switch (located on the OSC/PFL module). If a channel is muted (MUTE
switch ON), and the CHECK switch is pressed, the muted channel is unmuted, but all
other channels are forced into MUTE. This allows the originally muted channel(s) to
have a ‘SOLO’ function.
714185 53#
VHJPHQW
#
/('
#
PHWHU
The 20 segment LED meter continuously monitors the signal level in the channel,
pre-fader, unless the “MTR DIR O/P” switch is pressed (see 4.1.14). When the “MTR
DIR O/P” switch is pressed, the meter monitors the level of the channel’s direct out-
put circuit.
Summary of Contents for B-Type
Page 1: ...Audio Mixing Console 056 6 10 n 95 4 1 07 g8 2...
Page 6: ...vi General Precautions B Type Revision B2005 2...
Page 8: ...viii Introduction B Type Revision B2005 2...
Page 48: ...2 20 Central Control Module 7896 B Type Revision B2005 2...
Page 86: ...6 10 Group Module 7756 B Type Revision B2005 2...
Page 96: ...7 10 Grand Master Group module 7795 B Type Revision B2005 2...
Page 106: ...9 4 Auxiliary Output Module 7468 B Type Revision B2005 2...
Page 122: ...11 10 Osc Comms PFL module 7758 M Type groups B Type Revision B2005 2...
Page 130: ...12 8 Osc Comms PFL module 7635 F Type groups B Type Revision B2005 2...