![background image](http://html1.mh-extra.com/html/cadac/b-type/b-type_installation-and-user-manual_3239265010.webp)
1-2
Connecting the mixer systems
B-Type
Revision B2005-2
416
&RQQHFW
#
3RZHU
#
VXSSO\
#
V\VWHPV
41614
3RZHU
#
VXSSO\
#
V\VWHP
#
GHVFULSWLRQ
Cadac consoles are designed to allow the use of two independent power supply sys-
tems in a redundant configuration – “main” and “backup”. Both sets of power supply
units are used to power the console system so that under normal conditions, the
‘load’ is shared between the “main” and “backup” PSU’s. If a fault occurs in one of the
power units (causing it to ‘shut-down’), the remaining power unit will power the con-
sole.
For smaller B-Type consoles (consuming no more than 44A), it is possible to use the
8400 PSU. See
1.3.7 8400 switch-mode power supply unit
.
One ±18V PSU and one +13V/+48V PSU is referred to as a “PSU System”.
Designate one pair of power supply units as “SYSTEM 1" and the other as “SYSTEM
2". PSU System 1 and PSU System 2 should be connected to the same
phase
and
on the same ‘spur’, wherever possible. In situations where it is necessary to provide
a separate ‘feed’ to each PSU system pair, make sure that the cable lengths are the
same. This is to minimize any induced a.c. power input noise by ensuring that the
“EARTH IMPEDANCE” is the same for both PSU systems.
/
1
(
/
1
(
/
1
(
/
1
(
-
-
-
-
$5($
#
%5$1&+
#
3$1(/
$5($
#
%5$1&+
#
3$1(/
$5($
#
%5$1&+
#
3$1(/
*1'
#
%$5
*1'
#
%$5
1
#
/
0$,1
#
*5281'
#
5()(5(1&(
#
($57+
#
(/(&752'(
#
6<67(0
FIG 1-2. AC mains grounding diagram (single phase 200-240V)
368
#4
$
368
#4
%
368
#5
$
368
#5
%
Summary of Contents for B-Type
Page 1: ...Audio Mixing Console 056 6 10 n 95 4 1 07 g8 2...
Page 6: ...vi General Precautions B Type Revision B2005 2...
Page 8: ...viii Introduction B Type Revision B2005 2...
Page 48: ...2 20 Central Control Module 7896 B Type Revision B2005 2...
Page 86: ...6 10 Group Module 7756 B Type Revision B2005 2...
Page 96: ...7 10 Grand Master Group module 7795 B Type Revision B2005 2...
Page 106: ...9 4 Auxiliary Output Module 7468 B Type Revision B2005 2...
Page 122: ...11 10 Osc Comms PFL module 7758 M Type groups B Type Revision B2005 2...
Page 130: ...12 8 Osc Comms PFL module 7635 F Type groups B Type Revision B2005 2...