![background image](http://html1.mh-extra.com/html/cadac/b-type/b-type_installation-and-user-manual_3239265017.webp)
Connecting the mixer systems
1-9
Revision B2005-2
B-Type
4161:
;733#
VZLWFK
0
PRGH
#
SRZHU
#
VXSSO\
#
XQLW
CADAC 8400 switch-mode power supply units are designed to run from a minimum
of 208V up to a maximum of 260V a.c, 50/60Hz.
The 8400 is rated thus +13V@92A, ±18V@44A and 48V@5A.
The a.c. input is connected to the PSU via a 3-core cable, CMA reference 3183TQ –
BASEC approved, rated at 20A.
The 8400 unit is based on one POWER ONE RPMS-ETETGDGD1ETK Power block,
with additional circuitry as shown on CADAC drawing number C3.8397.
4161;
5HPRWH
#
VWDUW
#
RI
#;733#
368
Each 8400 switch-mode power supply provides the following outputs: 13v, ±18v and
48v. Each PSU is fitted with a front panel mounted 9-way 'D-type’ connector labelled
‘Connections for Remote Start’. If a remote start facility is used, Power Failure and
Over-Temperature LEDs may also be fitted with the remote start switches if required.
Fig 3-15 shows the circuit for starting up a “system” with a single switch. This has
proved to be the most popular method of connecting the remote start facility. This cir-
cuit can easily be extended to provide a single switch remote four all four PSUs if
required. If muliple switches are to be used, see fig 3-14.
NOTE:
■
■
■
■
The remote start switch must be a ‘momentary’ type. You can use 3 separate sin-
gle pole switches for each Power Supply to turn on 13v,±18v and 48v outputs of the
PSU alternatively use one single pole for the whole lot.
■
■
■
■
The remote switch(es) must be mounted on a metal panel.
■
■
■
■
Use shielded cable for the remote switch wiring.
■
■
■
■
The 9-way ‘D-type’ free plug must have a conductive shell. This is to ensure that
the cable shield connects directly to the PSU unit chassis.
■
■
■
■
Connect the cable shield to the metal panel where the remote switch(es) are
mounted.
FIG 1-10. 8400 power supply unit.
Summary of Contents for B-Type
Page 1: ...Audio Mixing Console 056 6 10 n 95 4 1 07 g8 2...
Page 6: ...vi General Precautions B Type Revision B2005 2...
Page 8: ...viii Introduction B Type Revision B2005 2...
Page 48: ...2 20 Central Control Module 7896 B Type Revision B2005 2...
Page 86: ...6 10 Group Module 7756 B Type Revision B2005 2...
Page 96: ...7 10 Grand Master Group module 7795 B Type Revision B2005 2...
Page 106: ...9 4 Auxiliary Output Module 7468 B Type Revision B2005 2...
Page 122: ...11 10 Osc Comms PFL module 7758 M Type groups B Type Revision B2005 2...
Page 130: ...12 8 Osc Comms PFL module 7635 F Type groups B Type Revision B2005 2...