![Cabletron Systems TRMIM-10R Installation Manual Download Page 49](http://html.mh-extra.com/html/cabletron-systems/trmim-10r/trmim-10r_installation-manual_479995049.webp)
CALCULATING RING LENGTH
Page C-10
Figure C-2. Building Cable Budget
Formulas
The formulas used to create the tables for the STP Cable Length
Worksheets yield values equal to the length of internal cabling
within wiring closets (see Figure C-3) in a multiple closet
configuration. The term Internal Trunk Length refers to
trunk cabling length within the wiring closet, adjusted to give
consideration to ARL. The actual calculation used in the table is
described as follows:
Internal Trunk Length =
2 x (TCU Patch Cables) +
(Rack to Rack Patch Cables) +
(Concentrator to Concentrator Patch Cables)
70'
95'
175'
55'
LONGEST
LOBE
Token Ring Corporation
WC-3
2 Racks
14 Concentrators
213 feet
WC-2
2 Racks
10 Concentrators
165 feet
WC-1
2 Racks
6 Concentrators
117 feet