INSTALLING THE TRMIM-10R
Page 3-6
2.
If a patch panel is being used, connect Ring-In from the patch
panel to Ring-In on the TRMIM-10R and Ring-Out from the patch
panel to Ring-Out on the TRMIM-10R. If connecting directly to
another concentrator, daisy-chain the connections, Ring-In to
Ring-Out, from concentrator to concentrator. For some
installations, DB-9 to MIC adapters may be needed.
3.4
FINISHING THE INSTALLATION
Complete the installation as follows:
1.
Be sure the MMAC and the stations are powered on.
2.
Check that the LEDs on the MIM and any LEDs on the stations
are indicating normal operation (TRMIM-10R red Error LED off
and no error indications at the stations). If you encounter errors
or abnormal operation, proceed to Chapter 4, Testing and
Troubleshooting.
The green Link Attached LEDs on the MIM should be illuminated
for each station that is inserted into the ring. The yellow 16Mb
LED should only be on if 16 Mbit/sec ring speed is desired.
3.
Configure the networking software.
The TRMIM-10R is now ready for operation. Before placing the
network into service, test the installation thoroughly, making sure
that all stations are able to be addressed and that the data is being
relayed without error. Ensure that the networking software is
configured properly to match the installed network.