Configuring the Trap Table
3-20
Trap Messages
BSCI: Invalid parameters
514
One or more parameters speciÞed in the Port Parameters record for this port is
invalid. This error disables the port.
Severity
Minor (Level 3)
Action
Correct the Port Parameters record, then reenable the port
([B],
[A], [C]
from the Main Menu). If this doesnÕt work, take the same
action as for message 500.
BSCI: Invalid port number or type
515
The port number and/or type speciÞed in the Port record is not valid for BSC
Interactive.
Severity
Minor (Level 3)
Action
Check the Port record.
BSCI: Invalid message transfer
516
Self-explanatory. This error disables the port.
Severity
Minor (Level 3)
Action
Take the same action as for message 500.
BSCI: Invalid circuit operations
517
An invalid operation has occurred and has disabled the port.
Severity
Minor (Level 3)
Action
Take the same action as for message 500.
BSCI: Invalid state event action
518
An invalid operation has occurred and has disabled the port.
Severity
Minor (Level 3)
Action
Take the same action as for message 500.
BSCI: Invalid buffer operations
519
An invalid operation has occurred and has disabled the port.
Severity
Minor (Level 3)
Action
Take the same action as for message 500.
BSCI: Invalid CRC operations
520
An invalid operation has occurred and has disabled the port.
Severity
Minor (Level 3)
Action
Take the same action as for message 500.
Summary of Contents for SPECTRUM 1800
Page 2: ......
Page 112: ...Frame Relay Status and Configuration 5 24 Viewing Frame Relay Status...
Page 124: ...X 25 Status and Configuration 6 12 Viewing X 25 Status...
Page 168: ...BSC Interactive Configuration 8 12 Configuring BSCI Devices...
Page 224: ...SmartSwitch 1800 Voice Configuration 12 20 Viewing Voice Statistics...