Configuring X.25 Physical Ports
6-7
X.25 Status and Configuration
Flow Control Negotiation
This Þeld allows for negotiation of ßow control parameters (packet and window
sizes for data transmission in either direction) on a per-call basis. If
No
is selected,
the
Default Packet Size
and
Setup Packet Window Size
will be used. If
Yes
is
selected, a packet and/or window size included in a call packet will be used. (If a
packet and/or window size is not included, the default values will be used.)
Throughput Class Negotiation
This Þeld allows for negotiation of throughput classes for data transmission in
either direction on a per-call basis. If
No
is selected, the
Default Throughput
Class
will be used. If
Yes
is selected, any throughput class included in a call
packet will be used. (If a throughput class is not included, the default value will
be used.)
Prevent Local Charge
This Þeld is used to prevent calls from being charged to this port. If
Yes
is
selected, incoming calls from the network with Reverse Charging speciÞed will be
rejected and outgoing calls will have Reverse Charging inserted if it is not already
in the call packet. If
No
is selected, then calls can be charged to this port.
Accept Reverse Charge
This Þeld is used to authorize the transmission of incoming calls that request
Reverse Charging. If
Yes
is selected, a call requesting Reverse Charging will be
accepted. If
No
is selected, and a call requests Reverse Charging, the call will not
be transmitted.
Fast Select
This Þeld authorizes transmission of incoming calls that request the X.25 Fast
Select facility. This Þeld must be set to
Yes
if SDLC-LLC2 conversion is conÞgured
over the port, or if the X.25 link is to an X.25 network.
In Call Bar
This is an X.25 facility that prevents the transmission of incoming calls to this
port.
Out Call Bar
This is an X.25 facility that prevents the transmission of outgoing calls from this
port.
Summary of Contents for SPECTRUM 1800
Page 2: ......
Page 112: ...Frame Relay Status and Configuration 5 24 Viewing Frame Relay Status...
Page 124: ...X 25 Status and Configuration 6 12 Viewing X 25 Status...
Page 168: ...BSC Interactive Configuration 8 12 Configuring BSCI Devices...
Page 224: ...SmartSwitch 1800 Voice Configuration 12 20 Viewing Voice Statistics...