Configuring the Trap Table
3-6
Trap Messages
LP Trn Frm/Sec exceeded T: “n” C: “n”
307
The RLP statistic
Transmitted Frames/Sec
has exceeded the threshold
(T: ÒnÓ)
that was set by the user. (
C: ÒnÓ
is the current value.)
Severity
Informational (Level 4)
Action
If this happens frequently, you may need to reroute some trafÞc.
LP Rej Frm/Sec exceeded T: “n” C: “n”
308
The RLP statistic
Rejected Frames/Sec
has exceeded the threshold
(T: ÒnÓ)
that
was set by the user. (
C: ÒnÓ
is the current value.)
Severity
Informational (Level 4)
Action
If this happens frequently, check the line for noise and check for
conÞguration errors on both the FRX port and the connected user
device.
LP Rtrn Frm/S exceeded T: “n” C: “n”
309
The RLP statistic
Retransmitted Frames/Sec
has exceeded the threshold
(T: ÒnÓ)
that was set by the user.
(
C: ÒnÓ
is the current value.)
Severity
Informational (Level 4)
Action
If this happens frequently, check the line for noise and check for
conÞguration errors on both the FRX port and the connected user
device.
Rcv Frm/Sec exceeded T: “n” C: “n”
311
The port statistic
Received Frames/Sec
has exceeded the threshold
(T: ÒnÓ)
that
was set by the user. (
C: ÒnÓ
is the current value.)
Severity
Informational (Level 4)
Action
If this happens frequently, you may need to reroute some trafÞc.
Tran Frm/Sec exceeded T: “n” C: “n”
312
The port statistic
Transmitted Frames/Sec
has exceeded the threshold
(T: ÒnÓ)
that was set by the user. (
C: ÒnÓ
is the current value.)
Severity
Informational (Level 4)
Action
If this happens frequently, you may need to reroute some trafÞc.
RTrn Frm/Sec exceeded T: “n” C: “n”
313
The port statistic
Retran Frames/Sec
has exceeded the threshold
(T: ÒnÓ)
that was
set by the user. (
C: ÒnÓ
is the current value.)
Severity
Informational (Level 4)
Action
If this happens frequently, check the line for noise, and check for
conÞguration errors on both the FRX port and the connected user
device.
Summary of Contents for SPECTRUM 1800
Page 2: ......
Page 112: ...Frame Relay Status and Configuration 5 24 Viewing Frame Relay Status...
Page 124: ...X 25 Status and Configuration 6 12 Viewing X 25 Status...
Page 168: ...BSC Interactive Configuration 8 12 Configuring BSCI Devices...
Page 224: ...SmartSwitch 1800 Voice Configuration 12 20 Viewing Voice Statistics...