Configuring the Trap Table
3-12
Trap Messages
Duplicate of DLCI “n” on Port
428
Each connection sharing a DLCI must be on a different logical port, and two
records have been conÞgured in the FRX specifying the same logical port on one
DLCI. (DLCIs are conÞgured in records for logical ports, IP/LLC2/IPX interfaces
over frame relay, and frame relay PVCs.) Only one of the duplicate connections
will come up.
Severity
Minor (Level 3)
Action
Check the database records for the duplicate conÞguration and
change one (or more) of the records.
File Update: FRDLCI.DAT
429
The Frame Relay DLCI conÞguration Þle has been updated.
Severity
Informational (Level 4)
Received Port Disable Request
430
Self-explanatory.
Severity
Critical (Level 1)
Action
None; however, all users of this port should be made aware of the
disable.
Received Port Dump Request
431
The BSC device has experienced a problem that caused it to send a request to send
a dump to the port.
Severity
Critical (Level 1)
Action
Check the device.
Node Under Remote Control
432
Self-explanatory.
Severity
Informational (Level 4)
Remote Control Released
433
Self-explanatory.
Severity
Informational (Level 4)
Remote Control CXN Clr cc= “n” dc = “n”
434
A remote control connection was cleared.
Severity
Informational (Level 4)
Action
Depends on the cause.
Summary of Contents for SPECTRUM 1800
Page 2: ......
Page 112: ...Frame Relay Status and Configuration 5 24 Viewing Frame Relay Status...
Page 124: ...X 25 Status and Configuration 6 12 Viewing X 25 Status...
Page 168: ...BSC Interactive Configuration 8 12 Configuring BSCI Devices...
Page 224: ...SmartSwitch 1800 Voice Configuration 12 20 Viewing Voice Statistics...