TPIM SPECIFICATIONS
B-2
B.2 TPIM-F2/F3 SPECIFICATIONS
The TPIM-F2 supports Multimode fiber optic cabling, and the TPIM-F3
supports Single mode fiber optic cabling.
TPIM-F2
The TPIM-F2 is designed to operate with 50/125
µ
m, 62.5/125
µ
m, and
100/140
µ
m fiber optic cable.
Table B-1
lists receiver sensitivity
parameters for the TPIM-F2, and
Table B-2
lists transmitter output power
parameters for the TPIM-F2.
.
Table B-1 TPIM-F2 Receiver Specifications
Test Conditions: T
A
: 25
°
C
Parameter
Typical
Minimum
Receive Sensitivity
-30.5 dBm
32.0 dBm
Peak Input Power
-7.6 dBm
-8.2 dBm
Rise Time
3.3 ns
Fall Time
3.3 ns
Bit Error Rate: Better than 10
-10
Table B-2 TPIM-F2 Transmitter Average Power
Test Conditions: T
A
: 25
°
C, Average power measured out of 10 meters of cable
Cable Type
Minimum
Typical
Maximum
Worst Case
Budget
Typical
Budget
50/125
µ
m
-16.02 dBm
-14.22 dBm
-12.42dBm 13.0 dB
17.5 dB
62.5/125
µ
m -13.5 dBm
-10.8 dBm
-9.0
16.0 dB
20.5 dB
100/140
µ
m -8.5 dBm
-5.85 dBm
-6.05
19.0 dB
23.5 dB
Bit Error Rate: Better than 10
-10