Chapter 5: Local Management
5-116
6H123-50 and 6H133-37 User’s Guide
256 - 511 Octets (Read-only)
Displays the total number of frames, including bad frames, received that
were between 256 and 511 bytes in length (excluding framing bits, but
including FCS bytes).
512 - 1023 Octets (Read-only)
Displays the total number of frames, including bad frames, received that
were between 512 and 1023 bytes in length (excluding framing bits, but
including FCS bytes).
1024 - 1518 Octets (Read-only)
Displays the total number of frames, including bad frames, received that
were between 1024 and 1518 bytes in length (excluding framing bits, but
including FCS bytes).
Index [XX] (Command)
This command is used to enter an index number for viewing statistics. For
instructions on how to use this command refer to
Section 5.33.1
.
CLEAR COUNTERS (Command)
This command is used to reset all statistic counters to zero. For details on
how to use this command, refer to
Section 5.33.2
.
5.33.1
Displaying RMON Statistics
To display the statistics for any index, proceed as follows:
1.
Use the arrow keys to highlight the Index [XX] field at the bottom of
the screen.
2.
Press the SPACE bar to increment (or press the DEL [delete] key to
decrement) the index number.
3.
Press ENTER (neither the RMON Index # field nor the statistics
change until ENTER is pressed).
5.33.2
Using the Clear Counters Command
To reset all the statistics counters of the selected interface to zero, perform
the following steps:
1.
Use the arrow keys to highlight the CLEAR COUNTERS command.
2.
Press ENTER, the counters for the selected index are reset to zero.
Summary of Contents for 6H123-50
Page 2: ......
Page 8: ...Notice vi 6H123 50 and 6H133 37 User s Guide ...
Page 14: ...Contents xii 6H123 50 and 6H133 37 User s Guide ...
Page 28: ...Chapter 1 Introduction 1 14 6H123 50 and 6H133 37 User s Guide ...
Page 50: ...Chapter 4 Troubleshooting 4 10 6H123 50 and 6H133 37 User s Guide ...
Page 186: ...Appendix A Specifications A 4 6H123 50 and 6H133 37 User s Guide ...
Page 204: ...Index Index 6 6H123 50 and 6H133 37 User s Guide ...