Broadcast Suppression Screen
6H123-50 and 6H133-37 User’s Guide
5-87
The following defines each Broadcast Suppression screen field:
PORT # (Read-Only)
Identifies the number of the switched port.
Table 5-6
shows the port
organization for each module.
Total RX (Read-Only)
Displays the total number of broadcast frames received.
Peak Rate (Read-Only)
Displays the number of broadcast frames received per second.
Time Since Peak (Read-Only)
Displays the time since peak broadcast frames received.
Threshold (Modifiable)
Enables the user to set the desired limit of receive broadcast frames that
will be forwarded per port per second.
Reset Peak (Toggle)
Enables the user to reset the peak rate. Resetting the Peak Rate also resets
the Time Since Peak field. The Reset Peak field toggles between YES and
NO.
Table 5-6
CONN/Port Organization
6H123-50
6H133-37
CONN 1 = Network Port 1, 10 Mbps
Network Port 2, 100 Mbps
CONN 1 = Network Port 1, 10 Mbps
Network Port 2, 100 Mbps
CONN 2 = Network Port 3, 10 Mbps
Network Port 4, 100 Mbps
CONN 2 = Network Port 3, 10 Mbps
Network Port 4, 100 Mbps
CONN 3 = Network Port 5, 10 Mbps
Network Port 6, 100 Mbps
CONN 3 = Network Port 5, 10 Mbps
Network Port 6, 100 Mbps
CONN 4 = Network Port 7, 10 Mbps
Network Port 8, 100 Mbps
HSIM = Port 7
Fast Ethernet Slot 5 = Port 9
Fast Ethernet Slot 6 = Port 10
Summary of Contents for 6H123-50
Page 2: ......
Page 8: ...Notice vi 6H123 50 and 6H133 37 User s Guide ...
Page 14: ...Contents xii 6H123 50 and 6H133 37 User s Guide ...
Page 28: ...Chapter 1 Introduction 1 14 6H123 50 and 6H133 37 User s Guide ...
Page 50: ...Chapter 4 Troubleshooting 4 10 6H123 50 and 6H133 37 User s Guide ...
Page 186: ...Appendix A Specifications A 4 6H123 50 and 6H133 37 User s Guide ...
Page 204: ...Index Index 6 6H123 50 and 6H133 37 User s Guide ...