Chapter 5: Local Management
5-46
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
Figure 5-19
Configuration Warning Screen
5.
Use the arrow keys to highlight the YES command and Press ENTER.
The changes are saved and the module reboots.
5.15.2
Setting the Subnet Mask
If the management workstation that is to receive SNMP traps from the
6E12X-26 and 6E13X-25 is located on a separate subnet, the subnet mask
for the 6E12X-26 and 6E13X-25 must be changed from its default.
To change the subnet mask from its default, perform the following steps:
1.
Use the arrow keys to highlight the Subnet Mask field.
2.
Enter the subnet mask into this field using Decimal Dotted Notation
(DDN) format.
For example: 255.255.255.0
WARNING!
174252
YOU HAVE ELECTED TO SAVE ONE OR MORE CONFIGURATION
ITEMS THAT REQUIRE RESETTING THIS MODULE.
ARE YOU SURE YOU WANT TO CONTINUE?
YES
NO