FE-100F3
The FE-100F3 shown in
Figure B-3
uses an SC style connector that
supports single mode fiber optic cabling. Specifications for the FE-100F3
are listed in
Table B-2
below.
Figure B-3
FE-100F3
Table B-2
Transmitter Power
Cable Type
Worst Case Budget
Typical Budget
8/125 µm fiber
>10.0 dB
<10.0 dB
12/125 µm fiber
>10.0 dB
<10.0 dB
NOTE
The transmitter power levels and receive sensitivity levels listed
are peak power levels after optical overshoot. A peak power
meter must be used to correctly compare the values given
above to those measured on any particular port. If power levels
are being measured with an average power meter, add 3 dB to
the measurement to compare the measured values to the
values listed above.