I/O Interface
12.3 Solution Examples
12.3.1 Peeling-off on Demand with Present Sensor PS800 / PS900
In the standard peel-off mode a label will be printed immediately after the previous label has been taken from the peel
position.
Using the I/O interface the print of the next label can be triggered by an external signal.
Requirements:
•
Operation with Present Sensor PS800 or PS900
•
External circuit as shown in Figure 28.
•
Setting
Printing > Print on Demand = "
On".
Operation:
Send a print job.
Activate
START
.
The first label will be printed and transported to the peel position.
Remove the label.
Activate
START
to start the next cycle.