![CAB SQUIX Configuration Manual Download Page 47](http://html.mh-extra.com/html/cab/squix/squix_configuration-manual_479052047.webp)
47
12
I/O Interface
Pin
Signal Name
Description
Activation / Active State
21
PEELPOS
Label in peel-off position
For peel-off mode only.
A label is in peel-off position.
+24 V on Pin 21
Bit 3
User Bit 3 is set
22
ERROR
General error message
The operation will be stopped and the error type will be
displayed.
0 V on Pin 22
23
STOP
Stop signal to interrupt the operation
Switch on +24 V between
Pin 23 and Pin 25
24
-
-
Do not use
25
GND_EXT
Ground of the external 24 V
Table 29
Pin assignment of the I/O interface
12.2 Circuit Diagram of Inputs and Outputs
Digital Inputs
•
conform to IEC/EN 61131-2 (Type 3)
•
Operating voltage: 24 V DC (9,6..35 V)
•
Switching logic: PNP switching
•
Low level „0“: < 7 V DC
•
High level „1“: > 11 V DC
•
Input current per channel: 1,5..2,5 mA (at 24 V DC)
•
Reverse polarity protection: yes
•
ESD protection: conform to IEC/EN 6100-4-4
Digital Outputs
•
conform to IEC/EN 61131-2
•
Operating voltage: 24 V DC (11..35 V)
•
Switching logic: PNP switching
•
Output current per channel: 625 mA
(overload protection)
•
Short-circuit protection: yes
•
Reverse polarity protection: yes
•
ESD protection: conform to IEC/EN 6100-4-4
Pin 20
P24_EXT
Pin 1
-
Pin 12
REPRINT
Pin 13
START
Pin 14
PAUSE
Pin 16
LBLREM
Pin 17
JOBDEL
Pin 18
RSTERR
Pin 23
STOP
Pin 25
GND_EXT
Pin 20
P24_EXT
Pin 3
-
Pin 4
FEEDON
Pin 5
-
Pin 9
JOBRDY
Pin 10
READY
Pin 15
RIBWARN
Pin 21
PEELPOS
Pin 22
ERROR
Pin 25
GND_EXT
Figure 26
Connecting inputs
Figure 27
Connecting outputs