20
20
I/O
Parameter
Meaning
Default
START mode
Configuration of the I/O signal START
Edge
: A label will be printed by switching on 24V between START and
GND_EXT.
Level
: In
Rewind mode
labels are printed as long as 24V are switched on
between START and GND_EXT.
In
Peel-off mode
a label will be printed after receiving the signal
LBLREM as long as 24V are switched on between START and
GND_EXT.
Edge
REPRINT mode
Configuration of the I/O signal REPRINT
Edge
: A label will be repeated by switching on 24V between REPRINT and
GND_EXT.
Level
: A label will be repeated as long as 24V are switched on between
REPRINT and GND_EXT.
START/REPRINT select
: A label will be repeated when 24V are switched on
between REPEAT and GND_EXT and the START signal will be activated
additionally.
Edge
Automatic LBLREM
Simulation of the I/O signal LBLREM
For peel-off mode without present sensor
On:
With the signal START the removing of the previous label also will be
confirmed.
Off:
To confirm the label removing the signal LBLREM must be activated.
Off
Table 16
Parameters of the
Setup > Interfaces > I/O
menu
6.1.9
Errors
Start menu.
Select
Setup > Errors.
Parameter
Meaning
Default
Error-Reprint
On:
With a correctable error and corresponding troubleshooting, the label
being printed when the error occurs is repeated.
Off:
Print job is continued with the next label.
On
Syntax error
Printer switches to error mode after receipt of an incorrect command.
On
Barcode error
On:
With faulty barcode contents or size specifications, printing is
interrupted.
Off:
Printing is not interrupted if an error occurs. If barcode contents
are faulty, the printer attempts to replace the incorrect data with valid
characters (e.g. zeros). If barcode size specifications are faulty, a gray
area is printed instead of the barcode.
On
Network error
Printer switches to error mode when problems with the network
connection occur.
Off
Table 17
Parameters of the
Setup > Errors
menu
6
Configuration