3-12
FlexNet
®
700 Series Line Extender
Rev F
3
Cable Attachment
➤
To attach cable
1. For each port, use
a #2 Phillips screwdriver to turn the centerseizure screw clockwise until it
just seats, then loosen it no more than two turns. Refer to Figure 3.8 as needed.
2. Remove the plastic cap or threaded plug from the cable entry port. Refer to Figure 3.8 as
needed.
Figure 3.8
Centerseizure
Assemblies (with RF
module removed)
3. If using heatshrink tubing, prepare a heatshrink boot according to specifications supplied by
the manufacturer. Be sure that the boot is long enough to cover the cable entry port insert
and the entire connector. The boot must also extend at least 2 inches (5cm) beyond the
back
nut. Slide the boot onto the cable and away from the cable end. (Refer to Figure 3.9.)
WARNING
: Hazardous voltages are present. Use approved safety procedures. Turn off all
power sources to the unit before installing the cable and connectors.
CAUTION
:
Do not back centerseizure screws out more than two full turns
.
Centerseizure screws are not captive. If backed out more than two full turns, the screws
may fall out into the housing and under the RF module, possibly causing short circuits
and definitely requiring removal of the RF module and service interruption.
Centerseizure Screws
Port
3
Port
1
Summary of Contents for FlexNet E7
Page 2: ...Introduction fm Page 10 Monday April 1 2002 12 43 PM...
Page 16: ...1 8 FlexNet 700 Series Line Extender Rev F 1...
Page 26: ...2 10 FlexNet 700 Series Line Extender Rev F 2...
Page 64: ...4 22 FlexNet 700 Series Line Extender Rev F 4...
Page 82: ...A 6 FlexNet 700 Series Line Extender Rev F A...
Page 88: ...B 6 FlexNet 700 Series Line Extender Rev F B...
Page 102: ...C 14 FlexNet 700 Series Line Extender Rev F C...
Page 104: ...D 2 FlexNet 700 Series Line Extender Rev F D...
Page 110: ...Index 4 Rev F...
Page 111: ...Introduction fm Page 10 Monday April 1 2002 12 43 PM...