Housing Instructions
3-13
3
Figure 3.9
Heatshrink Boot
4. Prepare the coaxial cable for attachment:
a. Prepare the cable end as recommended by the connector manufacturer.
b. Measure the center conductor length as shown in Figure 3.10.
c.
Ensure that the center conductor length is at least 1 1/8 inches (2.71 cm). If the center
conductor is longer than 1 1/4 inches (3.30 cm), trim it with wire cutters to between 1
1/8 and 1 1/4 inches (2.71cm and 3.30 cm) to avoid unintentional signal grounding.
Figure 3.10
Cable Connector
Assembly
5. Apply anti-seize compound to threads and O-ring. Do
not
use spray lubricant.
CAUTION
: Do not use feed-through type connectors. Use pin type connectors only.
Using connectors with center conductors exceeding 0.080 inches (2.03 mm) in diameter
will damage the centerseizure mechanism.
Entry Port
2 in (5.08 cm
)
Back Nut
Main Nut
Connector Body
Radiation
Sleeve
O-rings
Variations:
External threads
located on back nut.
Main Nut/Connector Body
Back Nut
Minimum: 1 1/8 in. (2.71cm)
Maximum: 1 1/4 in. (3.30cm)
Not more than
0.080 in.
(2.03 mm)
diameter
Summary of Contents for FlexNet E7
Page 2: ...Introduction fm Page 10 Monday April 1 2002 12 43 PM...
Page 16: ...1 8 FlexNet 700 Series Line Extender Rev F 1...
Page 26: ...2 10 FlexNet 700 Series Line Extender Rev F 2...
Page 64: ...4 22 FlexNet 700 Series Line Extender Rev F 4...
Page 82: ...A 6 FlexNet 700 Series Line Extender Rev F A...
Page 88: ...B 6 FlexNet 700 Series Line Extender Rev F B...
Page 102: ...C 14 FlexNet 700 Series Line Extender Rev F C...
Page 104: ...D 2 FlexNet 700 Series Line Extender Rev F D...
Page 110: ...Index 4 Rev F...
Page 111: ...Introduction fm Page 10 Monday April 1 2002 12 43 PM...