background image

 

 

 

 

 

 

 

 

 

 

 
 

 
 

ZXT-120 

(Z-Wave-to-AC IR Extender) 

 

 
 
 

 

 

Firmware Version: V1.0 and V1.1

 

Summary of Contents for ZXT-120

Page 1: ...1 ZXT 120 Z Wave to AC IR Extender Firmware Version V1 0 and V1 1...

Page 2: ...120 Information 9 Listening Mode Change 11 IR Code Selection 11 IR Code Learning 13 Reset ZXT 120 to factory default 17 INSTALLATION 18 MOUNTING THE ZXT 120 TO A WALL 18 WIRELESS INFORMATION 21 MAINT...

Page 3: ...Slaves FLiRS or Always Listening node after exclusion process before inclusion process FLiRS node type is for battery operated applications and it will enter sleep mode frequently in order to conserv...

Page 4: ...n work with any Z Wave compliant controller or gateway supporting the following Z Wave commands Configuration Command Class Multilevel Sensor Command Class Thermostat Command Class Thermostat Mode Com...

Page 5: ...troller The first controller is used to set up your devices and network Only the Primary Controller can be used to include or delete devices from a network It is recommended that you mark the primary...

Page 6: ...ssis Mount the battery cover into the main unit with 2 screws Check the polarity of the batteries and the marks inside the battery compartment Insert the batteries Push the battery cover and main unit...

Page 7: ...uct Overview Figure 2 PROG Key and IR Port of ZXT 120 Temperature sensor PROG Button Learning and LED Indication External IR Port USB Power 5V DC Battery chassis Surround IR Output for top and 4 direc...

Page 8: ...action was unsuccessful please repeat the procedure 3 User can use either primary controller or secondary controller should support configuration command class to setup the ZXT 120 AC code by the para...

Page 9: ...Note The status value 0x01 and 0x04 will be reset to 0 when the ZXT 120 receive a get command to this parameter 0x00 Idle this IR channel is idle default 0x01 OK the latest learning process successful...

Page 10: ...ation as below Parameter Table 6 4 5 3 2 1 0 7 0 0 0 0 0 1 0 1 Bit Mask Byte 1 Location 0 7 Bit Mask Byte 2 Location 8 15 Bit Mask Byte 3 Location 16 23 Bit Mask Byte 4 Reseved 6 4 5 3 2 1 0 7 0 1 0 0...

Page 11: ...usion process do not change ZXT 120 operation mode while ZXT 120 is included in a network How to switch ZXT 120 listening mode from Always Listening to FLiRS or vice verse Step Setup Key LED Indicatio...

Page 12: ...ommand you set on Gateway Cool Heat Auto Temperature set etc repeat step 2 and 3 to select the next code on code list LED flashes once every time it receives a command from gateway L Important Informa...

Page 13: ...22 C cool which matches value 5 IR code to be learnt will locate at 5 in ZXT 120 Set your original air conditioner remote at 22 C cool and turn it off Besides temperature and mode you may set other de...

Page 14: ...on original remote before learning mode timeout Keep away from incandescent light and direct sunlight during learning Make sure IR Transmitter of your original remote alight with learning diode of ZX...

Page 15: ...OFF 1 ON resume 2 19 C cool 3 20 C cool 4 21 C cool 5 22 C cool 6 23 C cool 7 24 C cool 8 25 C cool 9 26 C cool Default Cool 10 27 C cool 11 28 C cool 12 19 C heat 13 20 C heat 14 21 C heat 15 22 C he...

Page 16: ...C Cool to air conditioner When user press Heat on gateway without setting temperature ZXT 120 will send the learnt data of 22 C Heat to air conditioner There is only one code for dry mode user can se...

Page 17: ...user should refer to Listening Mode section if you want to change the operation mode L Information If you are using Gateway or other Z wave controllers to operate ZXT 120 Please follow the instruction...

Page 18: ...ury if the ZXT 120 falls and breaks MOUNTING PROCEDURE PRECAUTIONS Do not modify parts or use the ZXT 120 in ways other than its intended use Doing so could cause the ZXT 120 to fall and result in an...

Page 19: ...he ZXT 120 key holes and the screw mounting positions are shown in the figure below Note 1 When mounting the screws to the wall leave a space between the wall and screw cap as shown in the figure 3 In...

Page 20: ...2 Insert USB plug or batteries and IR emitter cable so that they are firmly connected to the ZXT 120 5 When removing the ZXT 120 from the wall lift up the ZXT 120 then pull it towards you 6 Detach th...

Page 21: ...expose your ZXT 120 to dust strong sunlight humidity high temperatures or mechanical shocks 2 Do not use old and new batteries together as old batteries tend to leak 3 Do not use corrosive or abrasive...

Page 22: ...re is no response on the IR emitter socket why A ZXT 120 supports two IR power levels for the external IR emitter to avoid saturation of the IR receiver You can set the IR output power level by the Pa...

Page 23: ...unobstructed environment IR learning Max 23 commands Temperature Measurable range 32 104 F 0 40 C Operation 0 40 C Storage 20 60 C Powered by USB Power DC 5V 100mA or Dry battery AAA x 3pcs Dimension...

Page 24: ...Save heating NO Energy Save cooling NO Thermostat Set point Away heating NO Off YES Heat YES Cool YES Auto YES Auxiliary Emergency Heat NO Resume YES Fan only YES Furnace NO Dry Air YES Thermostat Mo...

Page 25: ...2 FAN COMMAND_CLASS_THERMOSTAT _MODE THERMOSTAT_ MODE_SET MODE 6 HEAT COMMAND_CLASS_THERMOSTAT _MODE THERMOSTAT_ MODE_SET MODE 1 DRY COMMAND_CLASS_THERMOSTAT _MODE THERMOSTAT_ MODE_SET MODE 8 MODE AU...

Page 26: ...OMMAND_CLASS_CONFIGURATI ON CONFIGURATIO N_SET VALUE 1 PARAMETER NO 33 SIZE 1 SWING SWING OFF COMMAND_CLASS_CONFIGURATI ON CONFIGURATIO N_SET VALUE 0 PARAMETER NO 27 SIZE 2 IR CODE SETUP COMMAND_CLASS...

Page 27: ...COMMAND_CLASS_BATTERY BATTERY_GET VERSION COMMAND_CLASS_VERSION VERSION_GET MANUF ER SPECIFIC COMMAND_CLASS_MANUFACTUR ER_SPECIFIC MANUFACTURE R_SPECIFIC_GE T TEMPERATURE SENSOR COMMAND_CLASS_SENSOR_...

Page 28: ...e that may cause undesired operation WARNINGS Changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment RISK OF F...

Page 29: ...nd any property damage or personal injuries arising from or related to the use of the device z Service trips to provide instruction on product use z Shipping costs for replacement products This warran...