background image

BELL/SIREN CONNECTION 

 
The Protégé Zone Expander provides a connection for 2 
electric bells/sirens with full monitoring of the lock circuit 
for tamper and over current/fuse blown conditions. The 
bell monitoring can be disabled if it is not required.  

 

Electronic Bell/Siren Connection 

 
ZONE INPUTS 

 
The Protégé 16 Zone Expander can monitor the state of 
up to 16 zone inputs such as magnetic contacts, motion 
detectors and temperature sensors. Devices connected 
to these zones can be installed to a maximum distance of 
300m (1000ft) from the Controller when using 22 AWG. 
The Controller supports normally opened and normally 
closed configurations with or without EOL resistors. 
 

 

EOL Resistor Zone Configuration 

 

 

No EOL Resistor Zone Configuration 

 

SPECIFICATION 

 
Power Supply 

DC Input Voltage 

16VAC 50/60Hz @ 40VA (Max) 

Operating Current 

280mA (Typical) 
1.2A (Max) 

Communication 

RS-485 

 

Isolated Module Network 

Outputs 

Bell Outputs   

2 x 1.8A (Max)  
Electronic Shutdown 
Load 2 8 Ohm 20W Siren 

Low Current   

2 x 50mA (Max) Open Collector 

Inputs 

Zone  

 

16 (10ms to 60sec Input Speed) 

Tamper 

 

1 (Normally Closed) 

Trouble Zone   

16 

Dimensions 

PCB Dimensions 

183mm X 162mm 

 

  7.2" 

6.4" 

 
*Specifications are subject to change without notice, please 
visit www.integratedcontroltechnology.com for the updated 
information. 

 
 
 
 
 

 

 

Unit C, 6 Ascension Place, Mairangi Bay, P.O. Box 302-340 

North Harbour, Auckland, New Zealand. 

Phone: +64 (9) 476 7124  

y

  Fax: +64 (9) 476 7128 

www.integratedcontroltechnology.com 

 

 

 

16 Zone Expander 

Quick Start Guide 

 

 

PRT-ZX16  

 
 
INTRODUCTION 

 

The PRT-ZX16 Protégé Zone Expander extends the 
number of zone inputs on the system by 16 and the 
number of PGM outputs by 4 (includes 2 monitored 
bell control outputs). 
 

 

Secure Encrypted RS-485 Module 
Communications 

 

16 Zone Inputs 

 

2 Monitored Bell Control PGM Outputs (High 
Current) 

 

2 Open Collector PGM Outputs (50mA) 

 

1.5A Switching Power Supply 

 

Intelligent Battery Charge and Monitoring 

 

Online and Remote upgradeable firmware 

 
For a full installation manual or more information on the 
Protégé System Controller and other Integrated Control 
Technology products please login to our website 
www.integratedcontroltechnology.com 

Reviews: