![BWT COVERDECK Installation And Operating Instructions Manual Download Page 48](http://html1.mh-extra.com/html/bwt/coverdeck/coverdeck_installation-and-operating-instructions-manual_2836664048.webp)
11.2
Errors
DISPLAY
MEANING
04370
M808
Er112
Er112: If the motor runs continuously for 5 minutes, the action is suspended
and the motor is shut down for a set period of time (20 seconds). No
operation is permitted during this time.
04370
M808
Er113
Er113 : If the motor is running at a frequency below the set limit (30Hz), it is
shut down for a set period of time (10 seconds). No operation is permitted
during this time. Check that the cover fasteners are undone and that axle
rotation is not blocked.
04370
M808
Er115
Er115 : This message is displayed if the counter does not change to indicate
cover position. The system freezes and must be reinitialised step 2 before it
can be restarted. Check all the connections between the control panel, the
connecting box and the motor. Check that the circuit breaker has not been
tripped. Recommence the programming procedure from step 2.
11.
OPERATION AND ERROR MESSAGES
After turning the key, there is a delay of 1.5 seconds before the motor starts, this is to avoid any excessively
sudden reversal of the cover direction.
The meanings of the various PLC displays are provided below
11.1
Verification of operation
DISPLAY
MEANING
04340
M808
The screen continuously displays the number of turns counted by the PLC.
If the motor position was properly indicated and the connections are correct,
the number displayed when the cover is rolled out (approx 0) will be less
than the number displayed when the cover is rolled up (can vary between
around 4000 for a 4 metre pool up to around 7500 for a 12 metre pool.
03505
M811
The key is set to “OUVERTURE” (open) and the cover rolls up. This verifies
that the PLC was correctly programmed.
03775
M810
The key is set to “fermeture” (close) and the cover rolls out. This verifies
that the PLC was correctly programmed.
NB!
IF THE INSTALLATION AND PROGRAMMING PROCEDURES ARE CORRECTLY PERFORMED, THE MOTOR WILL STOP IF THE
USER RELEASES THE CONTROL KEY WHILE THE COVER IS ROLLING OUT. RELEASING THE CONTROL KEY WILL NOT
STOP THE MOTOR WHILE THE COVER IS ROLLING UP.
IF THIS IS NOT THE CASE, REPEAT THE PROGRAMMING PROCEDURE FROM STEP 2, AS IT HAS BEEN CARRIED OUT
INCORRECTLY, THE COVER DOES NOT COMPLY WITH THE FRENCH STANDARD NF P 90-308, AND THE MANUFACTURER
DECLINES ALL RESPONSIBILITY FOR ANY CONSEQUENCES.
2019/01 - Indice de révision : N - Code : 34201
PROTECTION & SÉCURITÉ
48/60