![BWT COVERDECK Installation And Operating Instructions Manual Download Page 40](http://html1.mh-extra.com/html/bwt/coverdeck/coverdeck_installation-and-operating-instructions-manual_2836664040.webp)
The COVERDECK motor should be wired by an experienced professional according to the diagram above.
Install a 30mA ground fault circuit breaker upstream.
Cable and wire cross sections must be respected to ensure correct operation.
+
+
A T C
A
T
1
2
3
4
5
6
C
+
+
+
A T C
-
Alimentation 220V + terre
Bornier de raccordement du coffret électrique
3x2,5²
3x1² blindé ou 3x1² dont le diamètre
extérieur est inférieur à 8mm
Boîtier de
commande
à clef
3g4²
jusqu’à 20m
3g6²
jusqu’à 30m
HO7RNF
ou HO6RNF
3x1²
Vers moteur COVERDECK
(déjà câblé en usine)
+
+
+
+
Ph
1 0 2
A T C E
N
T
6.
ELECTRICAL WIRING
CAUTION
The earth terminal in
the control panel must
be connected to the
installation’s earth.
Control panel connection terminal
IMPORTANT
THE CONTROL PANEL SHUOLD NOT BE EXPOSED TO SUNLIGHT.
INSTALL THE KEY SWITCH IN AN AREA THAT ALLOWS AN UNINTERRUPTED VIEW OF THE WHOLE POOL.
ANY ALTERATION OF THE ORIGINAL EQUIPMENT SUCH AS:
- A MODIFICATION OF THE CONTROL PANEL
- INSTALLATION OF A REMOTE CONTROL
- REPLACEMENT OR MODIFICATION OF THE KEY SWITCH
WOULD CONSTITUTE A THREAT TO SAFETY. THE AUTHOR OF SUCH ACTIONS WILL BE HELD ENTIRELY ACCOUNTABLE
AND THE GUARANTEE WILL BE AUTOMATICALLY CANCELLED.
3g4
2
up to 20m
3g6
2
longer than 20m
HO7RNF or HO5RNF
Key
switch
To the COVERDECK motor
(pre-wired in the factory)
3x1
2
shielded or 3x1
2
with an outer
diameter less than 8 mm
220 V power earth
2019/01 - Indice de révision : N - Code : 34201
PROTECTION & SÉCURITÉ
40/60