Safety Instructions
This appliance shall only be used in an above ground open air situation with
natural ventilation, without stagnant areas, where gas leakage and products of
combustion are rapidly dispersed by wind and natural convection.
FIGURE D1
– Outdoor Area Example 1.
An enclosure with walls on all sides, but no
overhead cover.
FIGURE D4
– Outdoor Area Example 4. With the
open side at least 25% of total wall area and
30% or more in the total of the remaining wall
area is open and unrestricted.
FIGURE D5
– Outdoor Area Example 5. With the
open side at least 35% of the total wall area
and 30% or more in total of the remaining wall
area is open and unrestricted. In the case of
balconies, 20% or more of the total wall area
shall remain open and unrestricted.
FIGURE D2
– Outdoor Area Example 2
Within a partial enclosure that includes an
overhead cover and no more than two walls.
FIGURE D3
– Outdoor Area Example 3.
With both ends open.
Carbon Monoxide Hazard
Hanging The Appliance
Appliance Performance
This appliance can produce carbon monoxide, which has no odour. Using
it in an enclosed space (For example, caravan, tent, car or mobile home)
may cause DEATH.
OUTDOOR USE ONLY
– The appliance must be used outdoors only and is to be
operated no closer than 1000mm from the sides and 1000mm from above to all
combustible surfaces, fabrics, flammable materials & people
The appliance is designed to be hung upright against a non-combustible vertical
surface. Do not operate from a non-upright position. Doing so can be dangerous
and will damage the appliance.
During operation ensure that air inlets and the top exhaust are kept free from
obstructions and closure.
Important
– This appliance is designed to be used with a source water temperature
of 20°C or below. If the temperature of the outlet water exceeds 50°C the burners
will shut off; you will be required to turn the water flow off and back on to reignite
the burners.
This appliance is designed to raise the outlet water temperature by a maximum
(average) of 25°C above the source water temperature and can be adjusted by
the gas regulator and water regulator control knobs located at the front of
the device.
The following figures are diagrammatical representations of outdoor areas
suitable for use with this appliance. Rectangular areas have been used
in these figures – the same principles apply to any other shaped areas.
Any enclosure in which the appliance is used shall comply with one of the
following:
Open side at
least 25% of
total wall area
Open side at
least 25% of
total wall area
Both ends open
30 percent or more in total
of the remaining wall area
is open and unrestricted.
30 percent or more in
total of the remaining
wall area is open and
unrestricted.